Xilinx Alveo U50 Скачать руководство пользователя страница 16

16 

Alveo Programming Cable User Guide 
UG1377 (v2019.

1

) September 17, 2019 

 Legal Notices 

Please Read: Important Legal Notices 

The information disclosed to you hereunder (the “Materials”) is provided solely for the selection and use of Xilinx products. To 
the maximum extent permitted by applicable law: (1) Materials are made available "AS IS" and with all faults, Xilinx hereby 
DISCLAIMS ALL WARRANTIES AND CONDITIONS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING BUT NOT 
LIMITED TO WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, OR FITNESS FOR ANY PARTICULAR 
PURPOSE; and (2) Xilinx shall not be liable (whether in contract or tort, including negligence, or under any other theory of 
liability) for any loss or damage of any kind or nature related to, arising under, or in connection with, the Materials (including 
your use of the Materials), including for any direct, indirect, special, incidental, or consequential loss or damage (including loss 
of data, profits, goodwill, or any type of loss or damage suffered as a result of any action brought by a third party) even if such 
damage or loss was reasonably foreseeable or Xilinx had been advised of the possibility of the same. Xilinx assumes no 
obligation to correct any errors contained in the Materials or to notify you of updates to the Materials or to product 
specifications. You may not reproduce, modify, distribute, or publicly display the Materials without prior written consent. 
Certain products are subject to the terms and conditions of Xilinx’s limited warranty, please refer to Xilinx’s Terms of Sale 
which can be viewed at

 https://www.xilinx.com/legal.htm#tos

IP cores may be subject to warranty and support terms 

contained in a license issued to you by Xilinx. Xilinx products are not designed or intended to be fail-safe or for use in any 
application requiring fail-safe performance; you assume sole risk and liability for use of Xilinx products in such critical 
applications, please refer to Xilinx’s Terms of Sale which can be viewed a

https://www.xilinx.com/legal.htm#tos

. 

AUTOMOTIVE APPLICATIONS DISCLAIMER 

AUTOMOTIVE PRODUCTS (IDENTIFIED AS “XA” IN THE PART NUMBER) ARE NOT WARRANTED FOR USE IN THE 
DEPLOYMENT OF AIRBAGS OR FOR USE IN 

APPLICATIONS THAT AFFECT CONTROL OF A VEHICLE (“SAFETY 

APPLICATION”) UNLESS THERE IS A SAFETY CONCEPT OR REDUNDANCY FEATURE CONSISTENT WITH THE ISO 
26262 AUTOMOTIVE SAFETY STANDARD (“SAFETY DESIGN”). CUSTOMER SHALL, PRIOR TO USING OR 
DISTRIBUTING ANY SYSTEMS THAT INCORPORATE PRODUCTS, THOROUGHLY TEST SUCH SYSTEMS FOR 
SAFETY PURPOSES. USE OF PRODUCTS IN A SAFETY APPLICATION WITHOUT A SAFETY DESIGN IS FULLY AT THE 
RISK OF CUSTOMER, SUBJECT ONLY TO APPLICABLE LAWS AND REGULATIONS GOVERNING LIMITATIONS ON 
PRODUCT LIABILITY. 

© Copyright 2019 Xilinx, Inc. Xilinx, the Xilinx logo, Alveo, Artix, Kintex, Spartan, Versal, Virtex, Zynq, and other designated 
brands included herein are trademarks of Xilinx in the United States and other countries. All other trademarks are the property 
of their respective owners. 

Send Feedback

Содержание Alveo U50

Страница 1: ...Alveo Programming Cable User Guide UG1377 v2019 1 September 17 2019...

Страница 2: ...rovided names of the supported cards and links to each Chapter 2 Preventing ESD Damage Updated Figure 1 Updated Tables 1 4 Chapter 3 Setting Up the System Updated Figures 2 7 Revised steps to set up r...

Страница 3: ...Component Descriptions 6 Chapter 3 Setting Up the System with the Programming Cable 8 Connecting the Ribbon Cable 8 Disconnecting the Ribbon Cable 10 Connecting Alveo Programming Module to Card 10 Cha...

Страница 4: ...Alveo programming cable consists of a programming module ribbon cable and USB cable Debug port enabled Alveo cards have a 2x15 pin connector which connects to the programming module via the ribbon cab...

Страница 5: ...nd Alveo card Used for programming the FPGA 2 Micro USB Connector Port 1 Provides connection between host system with Vivado installed and the programming module Used for programming the Alveo card 3...

Страница 6: ...ions Debug Header for Main Board Interconnection The programming module is populated with a 2x15 pin debug connector Callout 1 in Figure 1 which connects to the Alveo card via a ribbon cable 2x15 Conn...

Страница 7: ...Description MANF MANF_P N Remarks 1 1 Ribbon Cables IDC Cables 050 Tiger Eye IDC Ribbon Cable Assembly 1 27 mm 30 Position 6 length Female to Female Samtec FFSD 15 D 06 00 01 N Connection between pro...

Страница 8: ...ey IMPORTANT The ribbon length you use can vary depending on your system setup For ribbon cable length greater than 5 it is necessary to reduce the JTAG transfer frequency used by Vivado hardware mana...

Страница 9: ...apply gentle pressure and ensure the cable has a tight connection IMPORTANT Do not apply excessive force when connecting the ribbon cable as the connector pins can be damaged or bent CAUTION When inst...

Страница 10: ...er for ribbon cable access 1 Before installing the Alveo card connect one end of the ribbon cable to the 2x15 pin maintenance port on the Alveo card following the instructions outlined in Connecting t...

Страница 11: ...Alveo Programming Module An image of both the ribbon on the left side and USB connected on the right side is shown below Figure 7 Alveo Programming Module with Ribbon and USB Cables Connected 7 Guide...

Страница 12: ...on your host machine or laptop Alveo card must be installed see Connecting Alveo Programming Module to Card and the server powered on DMC connected as described in Connecting Alveo Programming Module...

Страница 13: ...e manager command line as shown in the below image set_property PARAM FREQUENCY 1000000 current_hw_target Figure 9 Changing JTAG Transfer Frequency via TCL Command 5 Choose the memory configuration pa...

Страница 14: ...7 In the Address Range drop down list select Entire Configuration Memory Device 8 Click OK Figure 11 Program Configuration Memory 9 Disconnect the card in the Vivado hardware manager 10 Disconnect the...

Страница 15: ...endix A Board Specifications Dimensions Square Form Factor Height 2 5 inch 6 35 cm Length 2 5 inch 6 35 cm Thickness 5 0 062 inch 0 1574 cm Environmental Temperature for U200 and U280 Operating 0 C to...

Страница 16: ...rior written consent Certain products are subject to the terms and conditions of Xilinx s limited warranty please refer to Xilinx s Terms of Sale which can be viewed at https www xilinx com legal htm...

Отзывы: