background image

 

1829XIxb1526_fc c3    Page 

1 of 35

 

Atlas Compliance & Engineering, Inc. 

1792 Little Orchard Street 

San Jose, CA 95125 

Phone 408.971.9743 

Fax 408-971-9783 

Web www.atlasce.com 

.

.

.

.

.

.

.

.

.

.

 

 

Atlas Compliance & Engineering, Inc. 

 

Test Report Class A 

 

FCC CFR 47 Part 15 COMPLIANCE 

Part 15.107(b) and Part 15.109(b & g) Limits 

 
 

Xilinx, Inc. 

2100 Logic Drive 
San Jose, CA 95124  USA  
 
Product: 
   Specialized Reprogrammable Hardware 
Models: 
   A-U250-P64G & A-U250-A64G 

 

Test Report Number: 

1829XIxb1526_fc c3 

Date of Report: 

July 20, 2018 

 

This report contains 35 pages and may be reproduced in full only. 
Partial reproduction may only be done with the written consent of  
Atlas Compliance & Engineering, Inc. 

 

Testing Cert #1007.01 

Содержание A-U250-A64G

Страница 1: ...Part 15 COMPLIANCE Part 15 107 b and Part 15 109 b g Limits Xilinx Inc 2100 LogicDrive San Jose CA95124 USA Product Specialized ReprogrammableHardware Models A U250 P64G A U250 A64G TestReportNumber 1...

Страница 2: ...29XIxb1526_fc c3 Rev Change Description Reason Application Date Appvd DRAFT Preliminary version of report for review Applies to A U250 P64G A U250 A64G July 20 2018 MEB c1 Issue of final report Accept...

Страница 3: ...Under Test 12 Equipment Block Diagram 16 Test Setup Radiated Emissions 21 Test Setup Conducted Emissions 23 Appendix A EUT Setup and Requirements 24 Test Methods for Emissions 25 EUT Setup 25 Emission...

Страница 4: ...ost Port Termination s 11 Table 5 Class A 10 Meter Distance Radiated Limits 28 Table 6 Class B 10 Meter Distance Radiated Limits 28 Table 7 Class A Power Line Conducted Limits 28 Table 8 Class B Power...

Страница 5: ...ardware Models A U250 P64G A U250 A64G PurposeofTest TodemonstratethecomplianceoftheSpecialized ReprogrammableHardware A U250 P64G A U250 A64G withtherequirementsofFCCCFR47 Part15RulesandRegulationsto...

Страница 6: ...test the Specialized Reprogrammable Hardware A U250 P64G A U250 A64G to the standards listed below The tests were performed on samples of the equipment provided by Xilinx Inc Results of the tests are...

Страница 7: ...Manufacturing LLC 1 16 17 1 16 19 Chamber NPS 2301 5400 NPS Cable 45 ft 0110 IW Microwavw 1 16 17 1 16 19 Pre amp 9kHz 2GHz _ CPA9231A 3259 Schaffner 1 16 17 1 16 19 Pre amp 9kHz 2GHz _ LNA6901 74007...

Страница 8: ...le length Full Height x16 PCIe form factor 4 banks of DDR4 DIMM 72 bit wide memory ECC rated at 2400 MT s Two QSFP28 sites capable of data rates up to 25Gpps per channel On board re programmable flash...

Страница 9: ...1829XIxb1526_fc c3 Page 9 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 10: ...on and Block Diagram for further details Table 1 Equipment Under Test Model Description S N A U250 A64G Specialized Reprogrammable Hardware A U250 P64G Specialized Reprogrammable Hardware EUT Support...

Страница 11: ...Monitor CN 0W021K 64180 921 0M9L SK 8115 Dell USB Keyboard CN 0DJ331 71616 6BE 0SX5 M UVDell1 Dell USB wired Mouse 0815018097 I O Ports and Cables Table 3 EUT Port Termination s I O Port Cable Type Le...

Страница 12: ...12 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Equipment Under Test The photographs below show the condi...

Страница 13: ...1829XIxb1526_fc c3 Page 13 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 14: ...1829XIxb1526_fc c3 Page 14 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 15: ...1829XIxb1526_fc c3 Page 15 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 16: ...1829XIxb1526_fc c3 Page 16 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com A U250 A64G...

Страница 17: ...1829XIxb1526_fc c3 Page 17 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 18: ...1829XIxb1526_fc c3 Page 18 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com A U250 P64G...

Страница 19: ...1829XIxb1526_fc c3 Page 19 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com...

Страница 20: ...an Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Equipment Block Diagram Following is the block diagram of the test setup Refer to TEST CONFIGURATION pages for port connections...

Страница 21: ...las Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Test Setup Radiated Emissions The photographs below show worst case...

Страница 22: ...XIxb1526_fc c3 Page 22 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com The photograph below shows the EUT po...

Страница 23: ...tlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Test Setup Conducted Emissions The photographs below show worst cas...

Страница 24: ...29XIxb1526_fc c3 Page 24 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Appendix A EUT Setup and Requiremen...

Страница 25: ...equirements If the length of cable between pieces of equipment and the manufacturer did not provide specifications on their spacing the interval between different pieces of equipment was about 10 cent...

Страница 26: ...r at a bandwidth of 1 MHz During the primary radiated scan the EUT was powered up and operating in its defined test mode The frequency range of 30 MHz to 1000 MHz was then scanned with the antenna loc...

Страница 27: ...ances of 10 for a 10 kHz measurement bandwidth All readings within 25 dB of the limits were recorded and those emissions were then measured using the CISPR quasi peak detector at a bandwidth of 10 kHz...

Страница 28: ...age dB V 0 15 0 50 79 66 0 50 30 73 60 Table 8 Class B Power Line Conducted Limits Frequency MHz Limit Quasi Peak dB V Limit Average dB V 0 15 0 50 66 56 56 46 0 50 5 56 46 5 30 60 50 NOTE 1 The lower...

Страница 29: ...1829XIxb1526_fc c3 Page 29 of 35 Atlas Compliance Engineering Inc 1792 Little Orchard Street San Jose CA 95125 Phone 408 971 9743 Fax 408 971 9783 Web www atlasce com Appendix B Measurement Data...

Страница 30: ...5m Horn H 13182 09 50 0 59 50 9 50 10 1 5m Horn V 17614 14 49 2 59 50 10 30 185 1 5m Horn V 12974 10 49 1 59 50 10 40 185 1 5m Horn H 750 02 35 11 47 00 11 89 175 1 2m BiLog V Test Method ANSI C63 4...

Страница 31: ...6 00 21 54 N gnd 17 455 33 02 AV 60 00 26 98 L1 gnd Test Method ANSI C63 4 2014 Note L1 Line side Spec Limit 15 107 b Class A N Neutral side QP Quasi Peak AV Average COMMENTS System continuously runni...

Страница 32: ...3 meter test distance Peak Level Limit 1199 88 38 4 59 50 21 10 170 1 5m Horn H 1499 24 28 3 59 50 31 20 155 1 5m Horn H 2399 48 34 6 59 50 24 90 10 1 5m Horn H 8482 15 39 3 59 50 20 20 0 1 5m Horn H...

Страница 33: ...Scan Time Atten 0 15MHz 30MHz 5kHz 10kHz PK AV 20msec 0dB Blue Trace Peak Measurement Green Trace Average Measurement Final Measurement x QP AV at 2 second measurement time Table 12 Line Scan Data Fre...

Страница 34: ...MHz 5kHz 10kHz PK AV 20msec 0dB Blue Trace Peak Measurement Green Trace Average Measurement Final Measurement x QP AV at 2 second measurement time Table 13 Neutral Scan Data Frequency MHz Level dB V D...

Страница 35: ...ted by this equipment as received was found to be within the FCC CFR 47 Part 15 Class A limits for Radiated and Conducted emissions Additionally it should be noted that the results in this report appl...

Страница 36: ...Class A Digital Device tested per ANSI C63 4 2014 procedures Supplementary Information This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This de...

Страница 37: ...owing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 4 Where a device...

Страница 38: ...al fastened to the equipment by welding riveting or a permanent adhesive The label must be designed to last the expected lifetime of the equipment in the environment in which the equipment may be oper...

Страница 39: ...t has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter...

Отзывы: