1821XIxb1525_fc c2 Page
30 of 35
Atlas Compliance & Engineering, Inc.
1792 Little Orchard Street
San Jose, CA 95125
Phone 408.971.9743
Fax 408-971-9783
Web www.atlasce.com
Report of Measurements Conducted Data
The following table reports the results of the conducted measurements for the
Specialized Reprogrammable Hardware, A-U200-A64G
Table 10 - Six Highest Conducted Emission Levels
Frequency
MHz
Level
dB
V
Detector
Limit
dB
V
Margin
dB
Phase
PE
Termination
0.195
57.54
AV
66.00
-8.46
L1
gnd
0.195
57.15
AV
66.00
-8.85
N
gnd
0.195
63.23
QP
79.00
-15.77
N
gnd
0.195
62.21
QP
79.00
-16.79
L1
gnd
0.26
45.30
AV
66.00
-20.70
L1
gnd
0.26
45.04
AV
66.00
-20.96
N
gnd
Test Method:
ANSI C63.4-2014
Note:
L1 = Line side
Spec Limit:
15.107(b) Class A
N = Neutral side
QP = Quasi-Peak
AV = Average
COMMENTS: System continuously running with XBB Demo program as observed on the host PC monitor,
power source 115 VAC, 60 Hz. Ambient temperature 67
F and relative humidity of 37%. The ambient
temperature of the actual EUT was within the range of 10
to 40
C (50
to 104
F) unless the particular
equipment requirements specify testing over a different temperature range. The humidity levels were within the
range of 10% to 90% relative humidity unless the EUT operating requirements call for a different level. Test
software used to collect the emissions data from the ESPC receiver was EMI Test Software _ ESPC-K1 Version
2.02.06e from Rohde & Schwarz.