D.
Object Function Properties
1.
Mute: controls muting of certain channel(s) with only On or Off, two values
2.
Polarity: defines signal polarity change, only two values, On for revert (-) or Off
for positive (+).
3.
SignalLevel: Controls Gain for certain channel(s), with Max, Min and step
setting.
4.
SignalDelay: Controls Delay for certain channel(s), with Max 650ms, Min 0ms
and customized step.
5.
Mixer: Defines routing, Max 0dB while Min OFF (no sound output to specific
channel(s))
6.
Micgain: for adjusting Mic output volume in Min/Max.
7.
RelativeSignalLevel: adjusting Gain step from 0.25dB to 5dB.
8.
Preset: for preset confirguration
9.
Meter: for real time display of volume meter
10.
Compressor/Limiter Meter: for real time display of Compressor/Limiter meter
11.
Others: objects only serve as icons e.g.Image, Rectangle and Label.
E.
Note
1. UDP protocol is used for connection of multiple panels with single processor, while
TCP is for linking of single panel with only one unit. If meter for a project is needed,
UDP should be applied.
2. XPanelDesign will display panels both online (Status icon, Green) and offline (Status
icon, Red). Panels within a same network differentiate from others by its unique IP and
MAC, i.e. names can be the same.
3. Each object should be defined properly before upload, or error will be displayed in
yellow rectangle where it appears. Take Preset for example, you must first configure in
<CommandSetup>, then define the numbering of the preset, or else error will be
prompted if any step is incomplete.
4. Image path and image name can not contain Chinese, picture format only PNG.