XP Series User's manual - Page 20
A 48V DC voltage can be supplied to external microphone when the
Phantom Power is enabled. Phantom Power cannot be enabled indivually
for each input channel, all Mic input channel will automatically receive at
48V DC voltage. This will not affect Line input since they are disconnected
physically.
7.5 Device
Configuration
MODE:
The unit assigns the Input source for the corresponding outputs when the
Mode of Operation is changed. The crossover point parameters like the
filter type, cut-off frequency and slope have to be configured manually in
the Crossover Menu for each Output Channel.
Mode:
Out 1 Out 2
Out 3
Out 4
Out 5
Out 6 Out 7 Out 8
None Any
Any Any Any Any Any Any Any
Stereo
2-Way In1 In1 In2 In2 Any Any Any Any
Stereo 3-Way
In1
In1
In1 In2 In2 In2 Any
Any
Stereo 4-Way
In1
In1
In1 In1 In2 In2 In2 In2
*Note: The configuration mode configures the input sources when selected.
The user can change the source afterwards if desired. It does not keep the
configuration in memory.
7.6 Copy
Channels
Copy Channels from the source to the target. When the Source and
Targets are both Inputs and Outputs, all audio parameters will be copied.
When one of the Source or the Target is an input while the other is an
output, only the Level, Polarity, Delay, EQ, Crossover, and Channel Name
are copied.
SYSTEM Config
MODE:None