Initial Device Connectivity:

Xilica processors and control devices run on a network based infrastructure and are set up and controlled by 
a host computer via Ethernet using the Xilica Designer software.

A network connection can be made between the computer and processor using:
a) DHCP enabled Router or Server/Router combination (Recommended)
b) or a non-DHCP enabled network connection (i.e. PoE switches).

Note: DHCP enabled Router/switch gear should be turned on first, with all Ethernet cables connected to the 
hardware prior to powering on the Hardware. This will allow for proper handling of IP address distribution to 
the Hardware. The IP address assignment is automatic if connected to a DHCP enabled network.

A) DHCP enabled router or server/router combination (Recommended)

POWER MAINS: 90-240 VAC 50-60Hz, 20VA

FUSE: T2.5A-250V

I

O

Ethernet  Control

Designed and Engineered in Canada

IP Reset

G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  + 

G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  + 

INPUTS

OUTPUTS

USE ONL

Y WITH 250V FUSE

Power over Ethernet

POWER MAINS: 90-240 VAC 50-60Hz, 20VA

FUSE: T2.5A-250V

I

O

Ethernet  Control

Designed and Engineered in Canada

IP Reset

G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  + 

G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  +  G  -  + G  -  + 

INPUTS

OUTPUTS

USE ONL

Y WITH 250V FUSE

Wall Controls

PC or Mac

PC or Mac

B) Non-DHCP direct connection

NeuPanel:Device connection

Содержание NeuPanel Mini K1

Страница 1: ...1 NEUPANEL MINI User Manual...

Страница 2: ...ding prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT T...

Страница 3: ...ork 8 b To mains power 9 Install Xilica Designer software a Windows installation 10 b Mac installation 11 Xilica Designer s Network View a Device network status 12 b Connection troubleshoot 13 14 c Ma...

Страница 4: ...graphics card 4 GB of RAM External power supply is included but it is recommended to use a PoE router switch Ethernet cable Cat5 6 Getting Help Additional Help Files and video tutorials are available...

Страница 5: ...Mini K4 Control any four value changes including gains threshold frequency etc NeuPanel Mini S4 Control any four buttons in the system design including Preset selection NeuPanel Mini S8 Control any ei...

Страница 6: ...nly that an Ethernet cable is connected to the processor Proper Network connection is displayed in Xilica Designer s Network view For more detail please refer to Network view on Page 12 On off push bu...

Страница 7: ...ernet Power supply connector Power the device using the included external power supply If you are sending Power over Ethernet PoE the external power supply is not needed IP Reset button Reset the IP A...

Страница 8: ...ering on the Hardware This will allow for proper handling of IP address distribution to the Hardware The IP address assignment is automatic if connected to a DHCP enabled network A DHCP enabled router...

Страница 9: ...tored IP addresses or revert to its default IP address and thus refuse to connect We recommend performing an IP Reset Page 13 2 Multiple mini controls Non DHCP For multiple mini controls connected to...

Страница 10: ...k Install to continue 4 Allow the program to complete the installation process This may take a several minutes 5 When complete Windows will ask for permission to allow firewall access The suggested se...

Страница 11: ...download the latest version of the Xilica Designer software from the Xilica website www xilica com 2 Double click on the XilicaDesigner mpkg file saved on your computer 3 OSX will display an installat...

Страница 12: ...ays three colors red yellow and green Circled in Red Network Connection Indicators Green The device is Connected and operational Yellow The device is Connected and online but not operational Hovering...

Страница 13: ...be green indicating that the processor is connected online and operational Note If you are Not connecting via Wi Fi turn off your device s Wi Fi so the device can connect to the desired network If th...

Страница 14: ...irmware Upgrade The pop up message shown will print out an error code Retry the Firmware Upgrade again Device can communicate to Xilica Designer with UDP but cannot communicate with TCP 1 Right click...

Страница 15: ...the Network tab select Change Network Configuration to disable DHCP and to insert IP addresses manually It also provides two built in test procedures device security and device information along with...

Страница 16: ...IPv4 then Properties to access the manual IP settings 5 Set up your computer s IP address to be 192 168 1 X where X can be any value from 0 255 but unique from other manually assigned device IP addre...

Страница 17: ...ngs for your computers static address IP address 192 168 1 X X is any value from 0 255 but unique from other device IP addresses Subnet mask 255 255 255 0 Router 192 168 1 1 7 Click Ok and Apply to ap...

Страница 18: ...o view the current software version click on the About tab at the top of the software This window will display your current software version Matching the Firmware To assist you in determining which fi...

Страница 19: ...op left of each device 2 Save any design files from the device onto your computer All programmed data on the device will be erased during the upgrade process To save navigate to the File tab at the to...

Страница 20: ...rade can result in a complete corruption of the processor If this happens please follow the Xilica Designer Firmware Upgrade guide Note If more than one unit needs a firmware upgrade you can save time...

Страница 21: ...series DSP is rather different from Solaro series DSP therefore the two DSPs cannot be used in the same project file For more information please visit the Xilica Designer section in the Xilica website...

Страница 22: ...project in offline mode no devices connected and later go online when all devices are connected 2 Double click the Mini module to open the device The NeuPanel Mini S4K1 on off buttons and level contro...

Страница 23: ...To program the Mini S4K1 level control fader Double click the DSP module to open it Double click the parameter module that you d like to program Select the desired fader by holding Cmd Click Mac or Ct...

Страница 24: ...f buttons Select the desired buttons from the DSP module by holding Cmd Click Mac or Ctrl Click PC Click and drag the selected buttons onto a Mini S4K1 control button Programmed buttons will turn gree...

Страница 25: ...esigner User manual Simply click and drag the desired preset onto an available button on the wall control To change a control preset to another saved preset Select the button control that you would li...

Страница 26: ...the desired control that you would like to rename 3 In the Object Properties menu rename the control in the Label Text Remove a programmed control button 1 Select the desired button fader on the wall...

Страница 27: ...ject by clicking the File tab at the top left of the software and Save Or save your project using the save icon at the top right of the software 3 Once done each mapped module in the work area is a so...

Страница 28: ...work area is now a solid color This indicates that you are in online mode Also the previous Load Design to Device s button has now changed Switch to Design Mode Switching from Online mode to Design mo...

Страница 29: ...support xilica com and we ll connect you with a solutions engineer Alterna tively if you d like to speak to someone you can call the following numbers for immediate assistance North America Rest of wo...

Отзывы: