XIEGU COMMUNICATIONS
3. Operating instructions
3.1 Wiring connection method
3.1.1 Method for connecting XPA125B with X108G
The XPA125B can be directly connected to an X108G, which can then control
the band switching and ALC functions of the amplifier.
-
The ACC data cable supplied with the XPA125B is connected between
the ACC ports of the two units. Both connectors are the same so
either end of the cable can be connected to either socket.
Use suitable RF coaxial cable to connect the X108G ANT port to the
XPA125B
TRX port.
-
-
XPA125B ANT portshould beconnected to theantenna.
Note: The early version of the X108 cannot be directly connected to
the XPA125B because it does not have an ACC interface.
3.1.2 Method for connecting XPA125B with X5105
Use the dedicated connector CE-19 to connect. Also, set the ALC switch on the CE-19 to the
ON position.