FusionServer X6000 V6 Server
Technical White Paper
A Appendix
2021-07-16
51
Drive
Configu
ration
Number
of
Standar
d PCIe
Cards
Number
of OCP
3.0
Networ
k
Adapter
s
Number
of RAID
Controll
er Cards
Fan
Configu
ration
CPU
Configuratio
n
Maximum
Temperatu
re
and 6354, the supported operating temperature decreases. For details, consult the local
sales representatives.
⚫
For configurations not listed in the table, the operating temperature range is 5°C (41°F)
to 35°C (95°F). For special configuration and temperature requirements, contact
technical support.
Table A-4
Operating temperature limitations (server with 24 x 2.5" SAS/SATA/NVMe drives)
Drive
Configu
ration
Number
of
Standar
d PCIe
Cards
Number
of OCP
3.0
Networ
k
Adapter
s
Number
of RAID
Controll
er Cards
Fan
Configu
ration
CPU
Configuratio
n
Maximum
Temperatu
re
16 ≤
drives ≤
24
2
0
0
a
8080+
185 W < P ≤
205 W
35°C
P≤185W
35°C
2
1
0
a
8080+
185 W < P ≤
205 W
34°C
P≤185W
35°C
2
0
0
a
8080
185 W < P ≤
205 W
32°C
P≤185W
35°C
2
1
0
a
8080
185 W < P ≤
205 W
31°C
P≤185W
35°C
⚫
a: When NVMe drives are used, and the RAID controller card is configured for
SAS/SATA drives, the supported operating temperature may decrease.
⚫
By default, all configurations include optical modules.
⚫
When the server is configured with high-frequency, less-core processors such as 6346
and 6354, the supported operating temperature decreases. For details, consult the local
sales representatives.
⚫
For configurations not listed in the table, the operating temperature range is 5°C (41°F)
to 35°C (95°F). For special configuration and temperature requirements, contact
technical support.