FusionServer 2288H V6 Server
Technical White Paper
5 Hardware Description
2022-06-25
103
Table 5-43
NVMe drive indicators (VMD disabled)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and operating
properly.
Blinking at 2 Hz
Off
Data is being read from or written to the
NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The NVMe drive has completed the hot
swap process and is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
M.2 FRU Indicators
The server supports the Avago SAS3004iMR RAID controller card, which supports two M.2
FRUs.
Figure 5-72
M.2 FRU indicators
Table 5-44
M.2 FRU indicators
M.2 FRU Active
Indicator (Green)
M.2 FRU Fault
Indicator (Yellow)
Description
Off
Off
The M.2 FRU is not detected.
Steady on
Off
The M.2 FRU is inactive.
Blink
Off
The M.2 FRU is in the read/write or
synchronization state.
Steady on
Blink
The M.2 FRU is being located.
Blink
Blink
The RAID array is being rebuilt.
Off
Steady on
The M.2 FRU cannot be detected or