Technical data „XETEC Vector V 150.2“:
RMS Output power @4 Ohms: 2x75W
RMS Output power @4 Ohms: 1x180W in bridged mode
RMS Output power @2 Ohms: 2x90W
Max input Current (@13,8 V): 33 A
Idle current (no signal): 1,2 A
Fuse: 2x20 A
Total Harmonic Distortion (THD): <0,10 %
SNR: >90 dB (A)
Freq.Response (bypass mode): 20 Hz-40.000 Hz (in bypass mode)
Damping Factor; 302
Stability: >2 Ohm, (>4 Ohm in bridged mode!)
Input Sensitivity: 250 mV-4 V
Crossover frequencies: highpass 32 Hz-320 Hz lowpass 32 Hz-320Hz
highpass adjustable
Warranty: 1 Year (EU 2 Years)
Troubleshooting:
Fault
Cause
1. Power indicator LED is not lit
• Main fuse or fuse in amplifier blown?
• Remote wire properly connected? Is there remote voltage (12 V)?
• Amplifier overheated?
• Battery voltage low (<10,2 V)?
• DC on one of the speaker outputs?
• Overload
2. Distortions at medium level
• Please check the speaker connections for short-circuits
• Are the speakers OK?
• Radio volume turned up too high. Better turn up the amplifier’s level controls
3. Alternator whine and similar noise
• Bad ground connections?
• Use ONE ground contact only!
• RCA cables run too close to power cables?
In case of further trouble, please ask your local
XETEC
dealer for support.
– 9 –
Vektor_V_150.2_E 13.05.2003 8:21 Uhr Seite 9