Xerox© LCD Monitor User’s Manual

Before consulting service personnel, check the following 

chart for a possible cause and solution to the trouble you are 

experiencing.

Monitor will not turn on

 

 Make sure the power cord is plugged in.

No picture 

  Make sure the power cord is plugged in.

  Check the signal cable connecting the LCD monitor 

and the computer (refer to page 12-13).

  Press the 

    

button on the front panel of the monitor.

Poor picture or abnormal picture 

  Check the D-SUB cable connecting the LCD monitor 

and the computer (refer to page 12-13).

  Press the 

MENU

 button to adjust the Brightness 

Contrast option in the OSD.

  Adjust the Color Select option in the OSD.

  Press the 

AUTO

 button on the front panel of the 

monitor, to automatically adjust the display mode.

Out of range message appears 

 Press the 

AUTO 

button on the front panel of the 

monitor, to automatically adjust the display mode.

  Press the 

MENU 

button to adjust the V Position, H 

Position and H Size options in the OSD.

  If using Windows 9X/2000/XP, wait a few seconds; 

once Windows detects the problem, a dialog will 

appear allowing you to manually set up the video 

mode according to the preset mode timing chart 

  (refer to page 21). 

Troubleshooting

Содержание XR3 Series

Страница 1: ...User s Guide LCD Monitor XR3 Series XA7 19i XA7 17i ...

Страница 2: ...hout limitation material generated from the software programs which are displayed on the screen such as icons screen displays looks etc XEROX and all Xerox product names mentioned in this publication are trademarks of XEROX CORPORATION Other company trademarks are also acknowledged Changes are periodically made to this document Changes technical inaccuracies and typographic errors will be correcte...

Страница 3: ...llation Connecting Your LCD Monitor to a Computer 12 Method Analog D SUB Connection 12 Installing Your LCD Monitor 14 3 OSD Menu Using the OSD Menu 15 The OSD Options 16 The picture Options 17 The advanced Options 18 The options Options 19 The utilities Options 20 4 Technical Information Preset Mode Timing Chart 21 D SUB Connector PIN Assignment 22 Plug and Play 23 Visual Inspection 23 Troubleshoo...

Страница 4: ...ax 32 2 725 2513 Email rma proview repair com leo starckx proview repair com ASIA When disposing of Proview products in Asia please contact the following location to make arrangements for recycling Proview Technology ShenZhen Co Ltd North Block 21 23 Shatoukok Free Trade Zone ShenZhen China Mr Dennis Chang Tel 86 755 2526 1512 Fax 86 755 2526 1565 Email recycling proview com cn AMERICA When dispos...

Страница 5: ...Low Voltage Directive as amended by Directive 93 68 EEC The electro magnetic susceptibility has been chosen at a level that gives correct operation in residential areas business and light industrial premises and small scale enterprises inside as well as outside of the buildings All places of operation are characterized by their connection to the public low voltage power supply system ...

Страница 6: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient Relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outle...

Страница 7: ...manufacturer This equipment and recommended cart or stand should be handled with care Quick stops excessive force and uneven surfaces may cause the equipment and cart stand to overturn Do not disable the 3 wire grounding type plug The grounding pin on the 3 prong plug is an important feature Removing the grounding pin will increase the risk of damaging the equipment If you can not fit the plug into...

Страница 8: ...arranty Refer service to qualified personnel Always remove the power cord from the outlet before cleaning the equipment Never use liquid or aerosol cleaners on the equipment Clean only with a soft dry cloth Do not expose the equipment to extreme temperature or to direct sunlight as the equipment may heat up and suffer damage Do not install the equipment near any heat sources such as radiators heat ...

Страница 9: ...oduct s display is abnormal DISPOSAL OF WASTE ELECTRONIC EQUIPMENT BY PRIVATE HOUSEHOLDS WITHIN THE EUROPEAN UNION This sign indicates that this product may not be disposed of with your regular household waste The recycling and separate collection of such products is your responsibility Please drop off the above mentioned waste at a designated place for recycling waste electrical and electronic eq...

Страница 10: ...Colors will appear vibrant and lifelike producing superior image quality Plug and Play Capability Easy trouble free configuration and set up Anti Reflective Coating Special surface treatment on the LCD panel for high ambient light environments that provides excellent legibility by reducing glare Wall Mounting Capability Compatible with the VESA industry standard for wall arm mounts to save valuable ...

Страница 11: ...e included in the box If any items are missing please return this product to the original place of purchase CAUTION Be sure to save original box and all packing material for future transport of monitor AC Power Cord Package Contents LCD Monitor Quick Guide Warranty Card CD ROM Driver Manual ...

Страница 12: ... the OSD On Screen Display And press again to activate the desired setting LED The LED light indicates when the LCD monitor is activated green light indicates power on and amber light indicates power saving Turns the LCD monitor on and off AUTO Press to automatically adjust the display settings to optimize performance based on the D SUB signal 1 2 3 4 5 1 2 3 4 5 ...

Страница 13: ...power cord to the LCD monitor and wall outlet Refer to the owner s manual of the computer for connections In the process of connecting external equipment do not connect any AC power cords to wall outlets until all other connections are completed 2 Installation Connecting Your LCD Monitor to a Computer Method Analog D SUB Connection Connect to power source 2 Connect to the D SUB port 3 ...

Страница 14: ...check all connections NOTE Unplug the monitor before installation to avoid electric shock or damage NOTE The button is used for switching the LCD monitor on and off it does not disconnect the device from the main voltage To completely disconnect the main voltage please remove the power plug from the socket NOTE The LED indicator is green when the monitor operates normally and will turn to amber wh...

Страница 15: ...low to set up and install the monitor 1 The package contains Display unit Stand 2 Cover an even stable surface with a soft cloth Place the unit face down on the cloth Fit the stand onto the bottom of the display unit as shown then push until the two latches snap into their sockets LATCHES LATCH SOCKETS ...

Страница 16: ...ection of controls available 2 Press the or button to highlight the desired icon Then press the MENU button to activate the highlighted icon 3 Press the or button to select the desired adjustment icon Then press the MENU button 4 Press the or button to change the value of the selected item 5 Select the exit icon to exit the OSD 6 Repeat steps 1 through 4 to make further adjustments All changes are...

Страница 17: ...ure Adjusts picture settings such as brightness contrast advanced Allows selection of the general color tint CUSTOM COLOR WARM or COOL options Adjusts picture settings such as H V position H size and phase utilities Adjusts the setting of the display time of the on screen menu Allows selection of the language used on all the on screen menus reset Restores the factory settings exit Exits the on scr...

Страница 18: ... adjust Automatically adjust the display settings to optimize performance based on the D SUB signal brightness Controls the overall brightness contrast Controls the difference between the brightest and darkest regions of the picture h position Adjusts the position of the picture left and right in the window v position Adjusts the position of the picture up and down in the window phase Adjusts sign...

Страница 19: ...l Inclines colors toward the natural end of the spectrum Fixes the red green and blue component levels at factory settings they cannot be independently adjusted warm Inclines colors toward the red end of the spectrum Fixes the red green and blue component levels at factory settings they cannot be independently adjusted user Allows the user to adjust red green and blue color component levels indepe...

Страница 20: ... DESCRIPTION osd h position Moves the OSD left and right in the window osd v position Moves the OSD up and down in the window exit Exits the OSD menu 1 The options menu provides access to the following menus The options Menu picture advanced options utilities reset exit osd h position osd v position exit ...

Страница 21: ...nu osd background Controls the translucence of the on screen menu s background languages Allows selection of the languages used on all the on screen menus exit Exits the utilities menu 1 The utilities menu provides access to the following menus The utilities Menu picture advanced options utilities reset exit osd timeout 15 seconds osd background opaque translucent language exit ...

Страница 22: ...l IBM PC AT Dot X Line Horizontal Frequency kHz Vertical Frequency Hz 720 x 400 31 47 70 00 640 x 480 31 47 60 00 37 86 72 80 37 50 75 00 800 x 600 37 88 60 30 48 08 72 20 46 87 75 00 1024 x 768 48 36 60 00 56 48 70 10 60 02 75 00 1280 x 1024 63 98 60 79 98 75 1280 x 1024 resolution is not available in 15 LCD monitor Preset Mode Timing Chart 4 Technical Information ...

Страница 23: ...or User s Manual PIN DESCRIPTION 1 Red 2 Green 3 Blue 4 Ground 5 Self Test 6 Red Ground 7 Green Ground 8 Blue Ground 9 5 VDC 10 Ground 11 Ground 12 SDA FOR DDC 13 H Sync 14 V Sync 15 SCL FOR DDC 1 5 6 11 5 10 1 D SUB Connector PIN Assignment ...

Страница 24: ...d blue so there are about 4 million dots in total According to ISO 13406 2 Class II a maximum of 6 pixels and 7 subpixels may be defective i e a total of 25 faulted dots This corresponds to approx 0 002 of the entire screen surface Visual Inspection This monitor conforms to the VESA DDC Display Data Channel standard which means that when it is used with a DDC compatible video card the monitor is e...

Страница 25: ...ng the LCD monitor and the computer refer to page 12 13 Press the MENU button to adjust the Brightness Contrast option in the OSD Adjust the Color Select option in the OSD Press the AUTO button on the front panel of the monitor to automatically adjust the display mode Out of range message appears Press the AUTO button on the front panel of the monitor to automatically adjust the display mode Press...

Страница 26: ...net www xerox displays com or www xerox displays info MODEL XR3 17 XXR3 19 LCD Panel Panel Size 17 TFT LCD 19 TFT LCD Brightness 420 400 Contrast Ratio 500 1 500 1 Dot Pitch 0 264mm x 0 264mm 0 294mm x 0 294mm Max Resolution 1280x1024 1280x1024 Input Connector D SUB D SUB Power Source AC100 240V 50 60Hz AC100 240V 50 60Hz Power Consumption 48W 48W Dimension 378x382x192 mm 426x413x210 mm ...

Страница 27: ...ard Time TEXAS AUTHORIZED SERVICE CENTER 10849 KINGHURST SUITE 120 HOUSTON TX 77099 281 530 4100 281 530 4104 Fax Hours 8AM 6PM Central Time EUROPE AUTHORIZED SERVICE CENTER CONTACTS XOAL BVBA RAKETSRAAT 100 B 1130 BRUSSEL BELGIUM E EMAIL rma proview repair com http www proview repair com Hotline 00800 00 88 77 66 Fax 32 2 725 2513 Hours 10AM 12PM and 2PM 5PM Monday through Friday Authorized Servi...

Отзывы: