background image

-3-

Table of Contents

1. Introduction ......................................................... 4

1.1 Features ............................................................................... 5
1.2 Specifications ....................................................................... 7

2. Installing the Switch ........................................... 8

2.1 Packing List ......................................................................... 8
2.2 Panels .................................................................................. 9
2.3 Mounting the Switches ....................................................... 10

3. Making Network Connections ......................... 11

3.1 Network Switched Ports ..................................................... 11
3.2 10/100BASE-TX Fast Ethernet Ports .................................. 13
3.3 Fast Ethernet Fiber Slot ..................................................... 15
3.4 Making Trunk Connections ................................................. 18
3.5 Making Sniffer .................................................................... 20

4. LED Indicators .................................................. 21

4.1 LED Panels ........................................................................ 21
4.2 Interpretation ...................................................................... 21

5. Performing Network Management .................. 22

5.1 Management Support ......................................................... 22
5.2 Management objects .......................................................... 23
5.3 Setting IP Address ............................................................. 24
5.4 Console Management ........................................................ 24
5.5 Web Management .............................................................. 25
5.6 Telnet Management ............................................................ 25
5.7 SNMP Management ........................................................... 26
5.8 Support .............................................................................. 26

Содержание KS-801

Страница 1: ...1 10 100 Fast Ethernet Managed Switch with Fiber Connectivity KS 801 Operation Manual DOC 020419 KS801 K...

Страница 2: ...nce Characteristics of Information Technology Equipment This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio inter ference i...

Страница 3: ...ts 11 3 2 10 100BASE TX Fast Ethernet Ports 13 3 3 Fast Ethernet Fiber Slot 15 3 4 Making Trunk Connections 18 3 5 Making Sniffer 20 4 LED Indicators 21 4 1 LED Panels 21 4 2 Interpretation 21 5 Perfo...

Страница 4: ...anagement 37 7 1 Start Browser Software and Making Connection 37 7 2 Login to the Switch 38 7 3 Port Status 40 7 4 Port Statistics 41 7 5 Administrator 42 7 5 1 Basic 43 IP Address 44 SNMP Entries 45...

Страница 5: ...It also provides one Fast Ethernet Fiber slot for uplink to fiber backbone The key features of the switch units are Easy Migration With 10BASE T 100BASE T support the switch provides a non disruptive...

Страница 6: ...lot supports 100BASE FX ST fiber module for MM fiber 100BASE FX SC fiber module for MM and SM fiber 100BASE FX MT RJ fiber module for MM and SM fiber 100BASE FX VF 45 fiber module for MM fiber Self le...

Страница 7: ...le management via RS232 console port In band Telnet management over TCP IP network In band Web based management over TCP IP network In band SNMP management SNMPagentRFC1155 1157 MIB II private MIB SNM...

Страница 8: ...Power status TPPortLED Link Activity Speed Duplex Collision status per port Filtering rate 14 880 pps for Ethernet 10BASE T 148 8 Kpps for Fast Ethernet 100BASE TX and FX Forwardingrate 14 880 pps fo...

Страница 9: ...tries around the world Before connecting the supplied power cord into the switch check to see that the cord voltage and current rating conform to the standards of the country of operation 2 1 Packing...

Страница 10: ...100 Port 1 9 10BASE T 100BASE TXPort 1 9 Crossover SW Crossover setting switch for 10 100 Port 9 100 Fiber Slot 100M Fiber slot for Port 9 LEDindicators LED display for power and all port status AC p...

Страница 11: ...tion space between the switch and the objects around it DesktopMounting For mounting the switch into a 19 inch rack a pair of mounting brackets is included in the pack Install Rack Mount Brackets Inst...

Страница 12: ...on types one is 10 100BASE TX RJ 45 connector and the other is 100BASE FX fiber slot The Fast Ethernet fiber slot can accommodate one optional Fast Ethernet fiber module The following table lists the...

Страница 13: ...hrough UTP cable MDI RJ 45 connector is provided for easy uplink via standard straight through UTP to other device that supports MDI X RJ 45 connector The following table shows the pin assignments of...

Страница 14: ...g to a non auto negotiation device half duplex mode is used However the ports can auto detect the connection speed ManualConfiguration The ports are configured to be enabled for auto negotiation as fa...

Страница 15: ...ing straight through UTP cable make sure MDI X to MDI connection rule is followed The following figure illustrates the pin assignments of a straight through UTP and a crossover UTP cable Straight thro...

Страница 16: ...m length 800 T ST MM 2 Km 800 C SC MM 2 Km 800 SA SC SM 15 Km 800 S3 SC SM 30 Km 800 S5 SC SM 50 Km 800 JM MT RJ MM 2 Km 800 JS MT RJ SM 15 Km 800 VM VF 45 MM 2 Km MM Multimode fiber cable SM Single m...

Страница 17: ...odules Different type of modules is mounted with different fiber connector FiberModule Topview Fiber Jumper Setting The jumper group J1 on the module is used to enable or disable the fiber module The...

Страница 18: ...X Speed 100Mbps Duplex mode Full duplex or half duplex Wavelength 1300nm Fiber Connectors ST SC MT RJ VF 45 Fiber cable MM 50 125mm 62 5 125mm recommended SM 9 125mm recommended ModuleInstallation 1 T...

Страница 19: ...n be configured optionally as trunking ports through the network management operation Two trunking ports composes one trunk Two switch units can be cascaded through one trunk The aggregated bandwidth...

Страница 20: ...2 One trunking port can only belong to one trunk 3 Only one trunk can exist between two switch units 4 Crossover UTP cables should be used at the same time for one trunk connection The length of each...

Страница 21: ...for monitor traffic in switched networks Any switched port can be defined as a sniffer port which can monitor one or more port traffic Normally it is connected to a LAN analyzer equipment When doing s...

Страница 22: ...LED indicate the duplex mode used and collision status FX LED indicate the fiber module is installed and active The LED indicators labeled a port number on top are corresponding to a specific 10 100B...

Страница 23: ...ons and can be managed by using the following methods Direct console connection over an RS232 cable Web browser software from Internet or Intranet over TCP IP network Telnet software over TCP IP netwo...

Страница 24: ...e good bad drop packet counts Administrator Basic Management IP address settings SNMP settings Advanced Management Spanning tree protocol settings Trunking settings Sniffer settings Console Port Infor...

Страница 25: ...sole management before performing any in band management operation When you log on to the switch console port for the first time a sign on string appears and you are prompted for a console login name...

Страница 26: ...Microsoft Internet Explorer 4 0 or later on any platform Con nect to the managed unit using the IP address as URL address http xxx xxx xxx xxx Refer to Chapter 7 for more information 5 6 Telnet Manage...

Страница 27: ...ned in the standard MIB II and private MIB The supported MIBs are available in the supplied CD ROM of the switch Use the SNMP management application software to compile the MIB file first before perfo...

Страница 28: ...gin admin password Welcome admin INET Factory default Username admin Factory default Password 123 The main menu is shown as follows Management Switching Hub Setup Menu TCP IP stack for ARM vx xx 1 Set...

Страница 29: ...y IP xxx xxx xxx xxx WARNING change ip will kill all current net connec tion IPAddress Unique IP address designated to this switch Subnet Mask the subnet mask of the IP address specified above Gateway...

Страница 30: ...100 Full Enable 6 Unlink Disable 100 Full Enable 7 Unlink Disable 100 Full Enable 8 Unlink Disable 100 Full Enable 9 Unlink Disable 100 Full Enable The port status definitions are Port Status States...

Страница 31: ...000000 5 000000 000000 000000 000000 000000 000000 6 000000 000000 000000 000000 000000 000000 7 000000 000000 000000 000000 000000 000000 8 000003 000000 000000 000136 000000 000000 9 000000 000000 0...

Страница 32: ...osts to determine which port to select as a forwarding port You should assign lower numbers to ports attached to faster media such as full duplex and higher numbers to ports attached to slower media T...

Страница 33: ...a is not transmitted Learning The switch enters the Learning State if no path with a higher priority is found during the Listening State Learned entries are entered in the Unicast Destination Forwardi...

Страница 34: ...Address 192 168 0 5 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 254 Spanning tree Disabled Trunking Disabled Sniffering Disabled Port Control Enabled Speed Auto Duplex Auto Flow Control Enable...

Страница 35: ...d select Update Firmware command from the main menu of console management screen When Waiting message is shown on screen to indicate the switch is ready to receive file from console port 3 Execute the...

Страница 36: ...ecute the utility program SFTP EXE from your DOS window The command syntax is C WINDOWS SFTP n filename Enter n 1 COM1 2 COM2 filename the file name of the new firmware The prompts shown on DOS screen...

Страница 37: ...date data size is xxxxx Programming finished 5 When finishing the download reboot the switch to make the update effect 6 8 Remote Boot System Select 8 from Setup menu to reboot the system This reboot...

Страница 38: ...t IP Address for the Switch Before the switch can be managed from a web browser software make sure a unique IP address is configured to the switch Refer to Console Management for how to set IP address...

Страница 39: ...gin to the Switch When browser software connects to the switch successfully a Login screen is provided for you to login to the switch as follows Login Factory default Username Admin Factory default Pa...

Страница 40: ...n is performed In addition to the device image the screen supports the following func tions on left side 1 Home home page and device image 2 Port Status view all port status 3 Port Statistics view all...

Страница 41: ...rma tion includes Port No LAN Port number Link Status Up link is active Down no link Port Control Port function is enabled or disabled Speed Status Connection speed used on the port Duplex Status Dupl...

Страница 42: ...lly Send Bad number of packets transmitted unsuccessfully Send Abort number of packets aborted when transmission Receive Good number of packets received successfully Receive Bad number of packets rece...

Страница 43: ...43 7 5 Administrator Click Administrator to perform more management functions as follows Basic Advanced Console Port Information Port Controls Security Manager System Manager...

Страница 44: ...44 7 5 1 Basic Click Basic to view or modify the following settings IP Address SNMP Entries...

Страница 45: ...s of this switch Subnet Mask the subnet mask of the IP address specified above Gateway the IP address of default gateway router Click Apply to make the change effective immediately If you change the I...

Страница 46: ...46 SNMP Entries Use scroll bar to view all settings as follows...

Страница 47: ...act person Community string list list of authorized SNMP communities Trap Manager list list of SNMP trap managers Only SNMP managers who are in the Community list can access this device with the autho...

Страница 48: ...48 7 5 2 Advanced Click Advanced inmenutoperform Spanning Spanning Tree protocol settings Trunking Trunking settings Sniffer Sniffer settings...

Страница 49: ...the forwarding algorithm and allows duplicate frames to be forwarded To provide path redundancy Spanning Tree Protocol defines a tree that spans all switches in an extended network Spanning Tree Prot...

Страница 50: ...50...

Страница 51: ...51...

Страница 52: ...sest to the Root Switch Only one port on each switch is assigned as the Root Port Max Age Maximum Age Timer measures the age of the received protocol information recorded for a port and ensures that t...

Страница 53: ...e same priority value the lowest port number forwards the spanning tree frames Port Status Ports which are enabled can be in one of the follow ing states Listening Switches send messages to one anothe...

Страница 54: ...king ports Select one configuration from the following four options None No trunking Port 1 2 Use port 1 and port 2 to compose one trunk Port 7 8 Use port 7 and port 8 to compose one trunk Port 1 2 7...

Страница 55: ...list and one sniffer port Select one or more LAN ports into the monitored port list All port traffic of monitored ports will be forwarded to a designated sniffer port at the same time when the traffic...

Страница 56: ...switched port as a sniffer port Sniffer port can receive all port traffic forwarded from all monitored ports The sniffer port can not be one of the members of monitored port list Click Update to chang...

Страница 57: ...57 7 5 3 Console Port Information Click Console Port Information from Administrator sub menu to view console port information They are BaudRate Bit sec Data Bits Parity Check Stop Bits Flow Control...

Страница 58: ...to configure LAN ports The con figuration options are Port Control Enable Disable Speed Setting Auto 100M 10M Duplex Setting Auto Full Half Flow Control Setting Enable Disable Note Port Control enable...

Страница 59: ...59 7 5 5 Security Manager Click Security Manager to view or change user name and password...

Страница 60: ...60 7 5 6 System Manager Click System Manager to perform TFTP Update Firmware Remote Boot System...

Страница 61: ...and in stalled in the network to support the file transfer with the switch Specify the following information for TFTP operations TFTP Server IP Address IP address of the TFTP server where the firmware...

Страница 62: ...rmware to confirm update to the switch A reboot screen shows up afterward to request for a reboot operation Refer to next sec tion for more information The updated firmware file can be obtained from v...

Страница 63: ...63 Remote Boot System After a firmware upgrade you must reboot the switch to start new firm ware Click Reboot to reboot the switch...

Отзывы: