5.2
Cleaning the ADF
From time to time the pad assembly and feeding rollers may become
contaminated with ink, toner particles or paper dust. In this case the scanner
may not feed documents smoothly. If this occurs please follow the cleaning
procedures to return your machine to its original state.
The Cleaning Procedures
1) Soak a cotton swab with some isopropyl alcohol. (95%).
2) Press the ADF Release button on the upper-left. Open the front door slightly to
the left. Wipe the upper feeding roller by moving the swab from side to side.
Rotate the roller forward with your finger and repeat the cleaning steps above
until the entire roller is cleaned.
3) Wipe the ADF pad in one direction from top to bottom or the other way around.
Be careful not to damage the pick springs.
4) Close the scanner front door. Your scanner is now ready for use.
Feeding Roller
ADF Pad
ADF Release
button