Step 6

Remove PCR roller from saddle blocks. Set
PCR roller aside. (See Photo 9)

Step 5

Remove the drum and set aside in a light pro-
tected area.

Photo 5

Step 7

Remove the screws to the wiper blade and lift
out wiper blade. Remove waste toner using a
vacuum or dry, compressed air. 
(See Photo 10)

Photo 7

Photo 8

Step 8

Clean wiper blade with a soft dry cloth or dry,
compressed air. 

Apply padding powder to the blade edge and
reinstall. (See Photo 11&12)

Step 9

Clean PCR saddle blocks with cotton swab
and Anhydrous Isopropyl Alcohol. Clean PCR
using a dry, soft, lint-free cloth.

NOTE: If needed, de-ionized water can be
used to clean the PCR.
(See Photo 13&14)

Photo 9

Photo 10

2

PHASER 5400 Technical Instructions

Photo 6

Photo 11

Step 3

Rotate the cartridge to the fill plug
side. Repeat Step 2 to remove the
cartridge pin. Separate the cartridge
sections and put aside the toner
unit. (See Photo 5&6)

Step 4

Remove the screws holding the
metal drum axial and remove drum
axial. Remove screws holding white
plastic drum with contact and
remove white drum axial. (See
Photo 7&8)

Photo 12

Photo 13

Photo 14