QUERY REPLIES
Table G-2 shows non-SCS query reply summary without IPDS
module.
Table G-2. Summary query reply (Non-SCS without IPDS)
Byte
Value (Hex)
Description
00—01
000A
Length of structured field
02
81
Type = Query reply
03
80
Summary query reply
04
80
Summary query supported
05
81
Useable area query supported
06
85
Character Sets query supported
07
86
Color query supported
08
87
Highlight query supported
09
8F
OEM query supported (idata
specified)
Tables 3, 4, 5, 6, and 7 expand on the values summarized in table
G-2.
G-2
XEROX MRP FAMILY COAX COMMAND REFERENCE
Содержание 4215
Страница 1: ...XEROX Xerox MRP Family 4215 MRP 4219 MRP 4220 MRP 4230 MRP Coax Command Reference May 1995 720P12761...
Страница 10: ......
Страница 18: ......
Страница 22: ......
Страница 54: ......
Страница 124: ......
Страница 132: ......
Страница 136: ......
Страница 144: ......
Страница 170: ......
Страница 224: ......
Страница 248: ......