background image

 

For more information about Xerox environmental programs in North America, refer to: 

www.xerox.com/Environment

 

For more information about Xerox environmental programs in Europe, refer to: 

www.xerox.com/environment_europe

 

 

2 of 3

 

Product Safety Data Sheet

 

Number:

  08-3009 15-Dec-08

 

Revision: 

02  

 

 

WorkCentre 3210 

 

 

CHEMICAL EMISSIONS

 

Chemical Emission Test per:RAL - UZ122

 

The machine was tested under the conditions as specified in the standard inside a room of  7.2 m

3

 with 2 air 

changes per hour. 
PARAMETER

 

CONCENTRATION (

mg/m

3

)

 

EMISSIONS (

mg/h)

 

TVOC: 

.27 

3.93 

Dust: 

.125 

1.8 

Ozone: 

None Detected 

None Detected 

 

 

ACOUSTICAL NOISE

 

Tested in accordance to ISO 7779 and declared per ISO 9296. 

Sound Power Level 

LwAd (B)

 

Run: 

6.3 

Sound Pressure Level 

LpAd (dBA)

 

Standby: 

18.7 

Run: 

52.0 

 

ELECTRICAL AND MECHANICAL 
CERTIFICATIONS

 

 

 

Electrical Operating Voltage 

(Volts):

 

110-127

 

220-240

 

Frequency 

(Hertz):

 

50/60

 

50/60

 

Standard: 

UL60950-1

 

IEC60950

 

Certifying Body: 

UL

 

UL

 

Report Reference/License:   

E149091-A237-UL-2

 

E149091-A233-CB-2

 

 

ELECTRO-MAGNETIC COMPATIBILITY:

 

  

 

Electrical Operating Voltage 

(Volts)

110-127

 

220-240

 

Frequency 

(Hertz):

 

50/60

 

50/60

 

Standard: 

FCC Part15 SubpartB ClassB

 

2004/108EC

 

Certifying Body: 

Xerox 

Xerox 

Report Reference/License:   

LBE082396

 

LBE083154

 

 

SUPPLIES:

 

MSDS Number(s): 

A-1051

 

 

 
 