The gauges do not return to their
initial position when the cycle is
finished.
The circuit maintains the
pressure due to fluid
remaining in it.
Carry out a voluntary
disconnection.
Check the tank is
empty.
Call the technical
engineers.
There are fuel leaks in the circuit.
There is a leak in one of the
components.
Press OFF and
disconnect the battery.
Check there is no
leakage through the
joints.
Contact the technical
engineers.
XI. Maintenance
•
Filter: It is recommended to change the filter every 12 months or 50 operations.
•
Only specialized staff authorized by the distributor should handle or disassembly the equipment.
•
Never handle the machine while it is connected to the vehicle's fuel system.
Warnings
Precautions for use
•
Connect only to 12 Vcc.
•
Never handle the inside of the equipment.
•
Depressurise the fluid system before disconnecting or handling equipment connections (see section VII. Disconnection).
•
Never allow the hoses and connections to be in contact with the hot areas of the engine (Hoses maximum heat
•
resistance 120 ºC).
•
Take precautions so the electrical connection cables do not become deteriorated because an excess of temperature or
mechanical brush.
•
Check all the connections before starting the engine up and check for any possible fluid leaks once the system is pressurized.
•
If you observe an overheating of the vehicle's engine, stop the engine and depressurize the system. Press OFF and wait at least
15 minutes before handling the hoses.
•
Never start the machine up if inflammable liquid has been spilt in it. Dry and clean the machine and wait for a prudential period.
•
Do not allow the machine to be near any source of heat or flammable material.
•
Do not smoke during the operation.
•
Place the equipment on a flat and stable surface.
•
Do not submit the machine to a drastic force nor place any weight on it.
•
Always close the tank cap to avoid impurities from falling in.
•
When the 4-WAY FLUX is not going to be used during a long period of time, we recommend connecting it to a battery and do
the purging function without liquid. This is important to avoid problems with the pump.
•
Use for the individual protection: Protection glasses & gloves.