16
E N
N L
When installing the remote control, it is recommended to click the cable into the
remote port of the inverter as a last step. This is because of the risk of static
electricity during assembly.
Put t
he main switch of the inverter in the ‘
OFF
’ position. After this, the inverter can
be switched on and off by using the remote control.
Connection with the equipment
All inverters from the PurePower series have a socket for the connection of the
230VAC equipment. The models from 1500Watt have double sockets.
When connecting multiple users it is important that the total load (Watts) and
surge powers fall within the capacity specifications of the inverter.
Important
-
If the surge power is exceeded, the inverter will become heavily damaged.
Repair costs will not be covered by warranty.
-
Don’t mount the cables against the housing of the inverter.
The inverter in combination with other AC power supplies
In many situations it is desirable that the equipment will work on the mains supply
(or generator) when this is available. The inverter and mains supply (or
generator) then become one circuit. Pay attention to the following:
Important
At the presence of a second power supply (mains, generator) this 230VAC will
be parallel on the output of the inverter. This will damage the inverter heavily!.
The repair costs are not covered by warranty. If you want the equipment to work
on both an inverter and a second power source, then mount the power transfer
switch PTS 230-10 or PTS 230-25 from Xenteq.
The power transfer switch
takes care of automatic switch between the two 230VAC circuits. See
accessories on page 20.