Potential free contact
There is also a potential-free contact within the PTS 230-25. This can
be used for all kinds of purposes, such as switching on a generator if
the 230VAC is lost, switching on/off an inverter or generating a
(warning) signal. The maximum load is 8Amp.
You will find a grommet on the left side of the PTS
housing. Cut away the part that is needed to feed the
used cable through. Connect the cable to the relevant
blue connector using pressure connectors.
Important
-
The potential free contact can NOT be used in combination with the
X-com function (RJ45 connection). It is therefore not possible to
connect and use the two functions. Simultaneous use can result in
defects.
-
Because the connecting cable is routed into the housing, this will
affect the IP value. The specified IP classification in the specifications
will no longer be achieved.
W A R R A NT Y A N D S ER VIC E
Before sending back the device, always advice all information in this
manual first. In case of a malfunction, the device can be send to us directly
or you can choose to arrange the return with your dealer. The device must
be send prepaid. The PTS-series carries a two-year warranty from selling
date. The warranty period is only valid when the (copy) purchase ticket is
handed
over with the repair and the serial no. hasn’t been removed. The
warranty only covers the costs of parts and labour for the repair. The
warranty will lapse when a third party has attempted to repair the device
or when the Power Transfer Switch is not installed or used in accordance
with the instructions.
The use of this device is the responsibility of the costumer. The
manufacturer and importer cannot be hold responsible for any damage
resulting from use of the Power Transfer Switch.