![Xenteq PTS 230-20 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/xenteq/pts-230-20/pts-230-20_user-manual_882650007.webp)
7
EN
Attention:
for 230VAC equipment you do not want to operate via the
inverter, such as a battery charger, a separate circuit must be made. So if
you connect the entire 230VAC circuit to the switch box, all equipment will
automatically be switched to the 230VAC output of the inverter.
Mounting
1.
Open the housing by removing the screws on the top.
2.
On the 4 corners, you can install the accompanying screws into the
holes in the housing. In this way, the housing can be mounted on a flat
surface.
Connection
1.
Run the power cable from the mains input through the right swivel and
connect it to the 3 screw connectors on the PCB (MAINS INPUT). Refer
to the drawing.
2.
Run the power cable for the output / consumers through the middle
swivel and connect it to the 3 corresponding screw connectors on the
PCB (OUTPUT). Refer to the drawing.
3.
Tighten all swivels properly.
4.
Close the housing again. Press the included corner pieces on to the four
corners of the housing.
5.
Connect the power cord with plug (INVERTER INPUT) to the output of
the inverter/generator.
L=
phase (brown)
N=
neutral (blue)
PE= ground (green-
yellow)
OUTPUT MAINS INPUT
L N PE PE N L
INVERTER
INPUT
Inverter/
Output Mains
generator
Содержание PTS 230-20
Страница 13: ...13...