background image

NDX40 User’s Manual 

 

 

 

Xenotronix/TLI  

BATTERY CHARGER SPECIFICATIONS 

 
General Conditions: 25 °C (77 °F) 
 

 
 

 

 

 

Quick Charge Rate 

2C (C/.5) 

1C (C/1) 

.5C (C/2) 

.25C (C/4) 

Minimum Charge Current 

0.5 A / 500 mA 

0.5 A / 500 mA 

0.5 A / 500 mA 

0.5 A / 500 mA 

Maximum Charge Current 

2.5 A / 2500 mA 

2.5 A / 2500 mA 

2.5 A / 2500 mA 

2.5 A / 2500 mA 

Float Charge Rate (avg.) 

0.05C (C/20) 

0.025C (C/40) 

0.0125C (C/80) 

0.01C (C/100) 

Peak Float Charge Current 

0.27 * I

chg

 0.27 

I

chg

 0.27 

I

chg

 1.7 

I

chg

 

Battery Capacity (mAh) 

250 to 1250 

500 to 2500 

1000 to 5000 

5000 to 10000 

Normal Recharge Time (approx.) 

35 min. 

1 hr., 10 min. 

2 hr., 30 min. 

5 hr., 35 min. 

Back-up Timer (approx.) 

45 min. 

1 hr., 30 min. 

3 hr. 

6 hr. 

V Inhibit (approx.) 

1.5 min. 

3 min. 

6 min. 

12 min. 

V Detection Level 

Nominal -0.5% with respect to top level 

Number of Cells 

1 to 10     (for 11 & 12 cell applications, consult factory) 

Battery Chemistry 

Rechargeable Nickel-Cadmium (NiCd) and Rechargeable Nickel-Metal-Hydride (NiMH) 

Open-Circuit Voltage 

About 20 to 22 volts 

Input Rating 

115 or 230 VAC ± 10%,  50 – 60 Hz,  0.70 A (RMS) 

Line / Load Regulation 

± 2% maximum 

Ambient Operating Temperature 

15 to 35 ºC (59 to 90 ºF) 

Ambient Storage Temperature 

-40 to 80 ºC (-40 to 176 ºF) 

Dimensions 

W 5.5” (14 cm)  x  D 3.5” (8.9 cm)  x  H 2.9” (7.3 cm) 

Weight 

About 4 lbs (1.8 kg) with standard output cable 

Содержание NDX40 Series

Страница 1: ...User s Manual Rev 1 0 October 17 2006 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541 Tracy Road...

Страница 2: ...is Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the su...

Страница 3: ...Model NDX40 Automatic Battery Charger User s Manual Important Safety Instructions 1 Introduction 2 Operating Instructions 2 4 Custom Units Note 4 Maintenance Instructions 4 Battery Charger Specificati...

Страница 4: ...de rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The enclosure will become hot during the charge cycle DO NOT TOUCH o Connect...

Страница 5: ...is option is recommended for the quicker 2C and 1C charge rates to minimize the effects of overcharging When charging is complete the charger will enter a float charge mode where a lower current is pu...

Страница 6: ...ct a charged battery CAUTION This charger is not reverse protected Make sure the battery connector is properly wired or damage to the battery and charger may result when the charger is plugged in The...

Страница 7: ...TOM UNITS NOTE Xenotronix TLI can make custom units or modify our existing units to exactly match your charging needs Call our sales department for technical information and pricing Following are some...

Страница 8: ...l Recharge Time approx 35 min 1 hr 10 min 2 hr 30 min 5 hr 35 min Back up Timer approx 45 min 1 hr 30 min 3 hr 6 hr V Inhibit approx 1 5 min 3 min 6 min 12 min V Detection Level Nominal 0 5 with respe...

Страница 9: ...NDX40 User s Manual Xenotronix TLI 6 DIMENSIONS 115 CHARGING READY FRONT VIEW BACK VIEW TOP VIEW...

Отзывы: