Xenotronix HPX30 Series Скачать руководство пользователя страница 11

HPX30 User’s Manual 

 

 

 

Xenotronix/TLI  

less, of its maximum rated current. In the constant voltage mode the unit is regulating 
voltage and the battery is being properly charged. When the indicator first changes from 
yellow to green the battery should be more than 80% charged, depending on battery size. 
It may take an additional 16-24 hours to finish charging the battery to 100%. To insure a 
full charge and to help your battery keep its full capacity, we recommend the charger be 
left connected to the battery at all times. There is little danger of overcharging the battery 
if the above precautions are followed. 
 
If AC power is lost, then the battery must fully support the load. To prevent battery 
damage from over-discharging, we recommend the use of a low voltage disconnect 
(LVD). The LVD will cut off the load from the battery when the battery is discharged 
and, after AC power has been restored, the LVD will automatically reconnect the load 
after the battery has received a partial charge. 
 
This charger can support a continuous load up one half of its rated output current. For 
example: If the unit is rated for 1 A it will support a continuous load of 0.5 A. This will 
leave enough power to keep the battery properly charged and to recharge a discharged 
battery in the event of a power failure. 
 
If the load is not continuous, it can be greater than the maximum continuous load 
specification. However, when operating with a higher current load the battery may not 
keep its charge and may begin to discharge. The load must be shut off intermittently to 
insure the battery is kept charged and to allow the charger to cool down. 
 
If the load is greater than the maximum rated output current of the charger, the battery 
will become discharged. Allow for adequate recharge time.  
 

 
BATTERY CHARGER SPECIFICATIONS 

 
Output Ratings (standard calibration): 
Model   

      

 

HPX30-012P200       HPX30-24P100 

 

Charge Amps   

 

2 A 

 

 

1 A 

 

Maximum Continuous Load  1 A 

 

 

500 mA 

 

Voltage   

    

 

13.60 VDC 

 

27.20 VDC 

 

 
Other Models (standard calibration): 

 

Charge Amps   

 

see marking label  

Maximum Continuous Load   ½ of Charge Amps  
Voltage   

    

 

2.267 V/Cell   

 

Содержание HPX30 Series

Страница 1: ...User s Manual Rev 1 0 October 17 2006 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541 Tracy Road...

Страница 2: ...is Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the su...

Страница 3: ...erating Instructions 2 3 Charging Notes and Tips 3 4 Troubleshooting 4 Maintenance Instructions 5 Battery Charger Specifications 5 Battery Recommendations 6 Dimensions 6 Parallel Battery Charger Suppl...

Страница 4: ...maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The enclosure will become hot during the charge cycle DO NOT TO...

Страница 5: ...metal enclosure to ensure field reliability This unit is designed to automatically switch into a single stage float charge mode when the battery is charged A single stage parallel charger version is...

Страница 6: ...tages when warm This unit incorporates automatic temperature compensation of the output voltage It will increase the charge voltage in cold conditions and decrease charge voltage in warm conditions Fo...

Страница 7: ...placement NO CHARGE INDICATOR NOT CHARGING If the charger will not go into charge mode yellow indicator then the battery is probably already charged Try again with another battery which you know is no...

Страница 8: ...If necessary use a mild detergent Do not use an abrasive cleanser or spray cleaners directly onto the charger Do not immerse unit in water BATTERY CHARGER SPECIFICATIONS General Conditions 25 C 77 F...

Страница 9: ...charge current to be safely charged Consult the battery manufacturer or Xenotronix TLI Model Battery HPX30 12C200 12 V 20 AH HPX30 24C100 24 V 10 AH AH Ampere hours Lead Acid Batteries are nominally r...

Страница 10: ...UCTION This unit is a Parallel Charger version of the model HPX30 Battery Charger It is designed to simultaneously float charge a battery while supporting or supplementing a parallel load It may also...

Страница 11: ...ad after the battery has received a partial charge This charger can support a continuous load up one half of its rated output current For example If the unit is rated for 1 A it will support a continu...

Отзывы: