HPX10 User’s Manual
Xenotronix/TLI
5
the battery - there should be about 2.15 V/cell for a properly charged battery (divide the
battery voltage by two to get the number of cells). If the battery voltage looks correct
then you may be trying to charge a battery which has too large a capacity for the charger
(see charging notes and tips).
RATTLE - If you think you hear a rattle inside the charger it is probably only a loose
terminal strip screw. Once the output cable is attached and the screws are properly
tightened, the rattle should go away.
MAINTENANCE INSTRUCTIONS
CLEANING - Unplug the charger and disconnect the battery before attempting any
cleaning. If it becomes necessary to clean the enclosure, wipe the enclosure exterior with
a damp cloth. If necessary, use a mild detergent. Do not use an abrasive cleanser or spray
cleaners directly onto the charger. Do not immerse unit in water.
BATTERY CHARGER SPECIFICATIONS
General Conditions
25 °C (77 °F)
Operating temperature
0 to 40 °C (32 to 104 °F)
Storage temperature
-40 to 80 °C (-40 to 176 °F)
Dimensions
H 3.8" (9.65 cm) x W 2.8" (7.1 cm) x D 2.8" (7.1 cm)
Weight
Less than 1.5 lbs (0.68 kg) with standard output cable
Power Requirements
120 VAC, 60 Hz, 0.2 A
Output Ratings (standard calibration):
Model
HPX10-06C100 HPX10-12C080
Charge Amps
1000 mA
800 mA
Charge Voltage
7.20 VDC
14.40 VDC
Switch Amps
approx. 133 mA
approx. 107 mA
Float Voltage
6.80 VDC
13.60 VDC
Other Models (standard calibration):
Charge Amps
see marking label
Charge Voltage
2.40 V/Cell
Switch Amps
approx. Charge Amps/7.5
Float
Voltage
2.267
V/Cell
Safety Agency Approval
CSA NRTL/C
(USA and Canada)