Digital output control Registers
The base address for these registers is 8220
Byte
Offset
Name
RW
Bits
Description
Default
value
4h
DigitalOutputInvert
RW
31..0
Invert the selected digital output source
Bits #
Name
Function
0
DigitalOutput0Invert
Invert digital output
0
‘0’ False
‘1’ True
False
1
DigitalOutput1Invert
Invert digital output
1
‘0’ False
‘1’ True
False
31..2
Do not use
8h
DigitalOutputStatus
RO
31..0
Status of the selected digital output source
Bits #
Name
Function
0
DigitalOutput0Status
Status of the
selected digital
output0 source
True
1
DigitalOutput1Status
Status of the
selected digital
output0 source
True
31..2
Do not use
18h
DigitalOutput0Delay
RW
31..0
Delay in µs for the digital output 0
0
1Ch
DigitalOutput1Delay
RW
31..0
Delay in µs for the digital output 1
0
20h
DigitalOutput0PulseWidth
RW
31..0
Pulse width for the digital output 0
1
24h
DigitalOutput1PulseWidth
RW
31..0
Pulse width for the digital output 1
1
28h
DigitalOutput0Source
RW
31..0
Source for digital output 0
Bits #
Name
Function
2..0
DigitalOutput0Source
Digital output
source
0 : Disable
1 : High
2 : Low
3 : start of frame
4 : start of line
High
31..3
Do not use
2Ch
DigitalOutput1Source
RW
31..0
Source for digital output 1
Bits #
Name
Function
2..0
DigitalOutput1Source
Digital output
source
0 : Disable
1 : High
2 : Low
3 : start of frame
4 : start of line
High
31..3
Do not use
Table 6-12
Digital output control registers