General view

XDOM® PRO is provided with an electrical connection 

breakout, located on the module rear side, available for 

the Line (L), Ground (N), and Output (L1, optionally L2, 

optionally L3) connections. 

L3 L2 L1

Electrical supply

230 VAC - 50 Hz

Power absorption

Up to 2A for single line

Front glass colours

White - Black

Operating temperature range -20°C  -- +70 °C
Radio Protocol

Wi-fi + Bluetooth Low 

Energy (for specific 

operations)

Maximum range

Up to 60 m (open spaces)

Up to 30 m (close spaces) 

Dimensions

118mm x 72mm x 38mm

Device power consumotion

< 300 mW

Actuation element

Triac

Certification

CE, RoHS 

N

L

Содержание PRO ZERO

Страница 1: ...XDOM PRO User Manual...

Страница 2: ...anks for choosing XDOM PRO This user manual in cludes important information regarding security and prop er installation of XDOM PRO devices The package includes n 1 module also called device XDOM PRO...

Страница 3: ...rom wherev er in the world 24 hours per day 365 days per year After the XDOM PRO installation the user can monitor the ON OFF status of the connected equipment and change their status after login oper...

Страница 4: ...No particular settings are required to the Wi fi router e g ports firewalls etc Indeed the adopted Cloud system is structured in order to simplify the installation operations Moreover the XDOM PRO ar...

Страница 5: ...er usage Moreover the warran ty is no longer valid in case of incorrect installation i e any mounting operation different from the one described in this manual XDOM PRO can be installed even in pres e...

Страница 6: ...elevators and similar systems not equipped with emergency opening ON OFF of systems that can put in danger persons or animals As mere example it is explicitly forbidden to install XDOM PRO to control...

Страница 7: ...s available to direct usage from the cus tomer Therefore opening and manomission of the module can cause the warranty void Each XDOM PRO has the following features Line to 230VAC and Null connections...

Страница 8: ...he touch control is not re quired e g within the electrical motors boxes TYPICAL USE SCENARIO XDOM PRO ZERO can be used to generate the pulse con trol signal for an electrical gate therefore replicati...

Страница 9: ...for the remote control of a single electrical equip ment even if power demanding e g industrial machines via an additional external relay TYPICAL USE SCENARIO XDOM PRO ONE can be used to ON OFF a dom...

Страница 10: ...rol of shutters or to control two different equipment but locat ed in the same zone e g opening close of an access gate and ON OFF of illumination of the same environment TYPICAL USE SCENARIO XDOM PRO...

Страница 11: ...paces or to control two different equipment but lo cated in the same zone e g opening close of an access gate and ON OFF of illumination of the same environment via an additional external relay TYPICA...

Страница 12: ...L3 L2 L1 Electrical supply 230 VAC 50 Hz Power absorption Up to 2A for single line Front glass colours White Black Operating temperature range 20 C 70 C Radio Protocol Wi fi Bluetooth Low Energy for s...

Страница 13: ...ent Output lines have a maximum commutation of 2A when considering nominal 230V voltage To operate with pow er demanding loads it is necessary to place on the out put stage also power relays tailored...

Страница 14: ...TION Do not connect output loads exceeding the maximum value allowed for XDOM PRO output lines N b to provide Cloud communication XDOM PRO shall be installed in areas with sufficient preferred Wi Fi n...

Страница 15: ...NORMAL INSTALLATION 2A of absorbed current for output line NL L3 L2 L1 RELAY INSTALLATION 2A of absorbed current for output line NL COM NO COIL NC L3 L2 L1...

Страница 16: ......

Отзывы: