xDEEP Ghost Скачать руководство пользователя страница 17

15 Post-dive maintenance 

 

Disconnecting 

After  diving,  take  out  the  weight  from  the  weight  pockets  (if  applicable),  disconnect  the  LP  hose  from  the 
inflator, and then disconnect the tank. 

 

Draining 

Inflate the BC orally using the purge button of the inflator. Next turn the BC to keep the automatic dump valve 
at the lowest point of the BC. Pull the valve string, at the same time pressing the BC with your hands to make 
water flow out by the open dump valve. Repeat the procedure until all water is removed from the BC. 

 

Rinsing 

Every time you use the BC in salt or chlorinated water, it should be rinsed thoroughly inside and out with fresh 
water. Never use hot water for rinsing! 

To rinse the BC inside, press the purge button of the inflator and fill the BC approximately ¼ full with water by 
means of a  garden hose spout  or other source of fresh water.  Rotate the BC several times, and next drain it 
according to the above procedure. 

 

 

 

Drying 

After every use, you should dry the BC thoroughly. When drying, the BC should be fully inflated and hung in a 
dry, airy and dark place. When drying, do not expose your BC to direct sunlight or extreme heat! 

 

Storing 

Store your BC partially inflated and hung in a dry and dark place away from sharp objects, lubricants, fuels or 
solvents. 

 

 

 

Do not press the inflator button when rinsing your BC! This may make damp and other contaminants enter 

the inflator valve, which may cause subsequent damage to the valve. 

Warning! 

To prevent your BC from damage, you should never keep it wet for a longer period than a dozen or so 

hours. 

Warning! 

Содержание Ghost

Страница 1: ...User Manual...

Страница 2: ...oughly In no way can this manual act as a substitute for professional diver training or course Therefore before you start using any of the products described in this manual make sure that you have rel...

Страница 3: ...tified as compatible with 89 686 EWG directive as far as it contains air compatible with EN 12021 norm Regarding the lack of EN norms for safety requirements while the use of it takes place with mixtu...

Страница 4: ...to damage done to the BC or an uncontrolled ascent For bringing objects heavier than 2kg use appropriate equipment such as a lift bag 7 To prevent the BC from damage avoid prolonged exposure of your...

Страница 5: ...ess see Chapter 6 Optional droppable weights or trim pockets On the following pages of this manual we described particular elements of the system and also their configuration and adjustment 1 Compensa...

Страница 6: ...e is made of metal which makes the inflator more resistant to freezing and it can be operated much longer than inflators made entirely of plastic The inflator is equipped with an inflator button 1 to...

Страница 7: ...s from the waist strap if installed 2 Fix the pockets on the waist strap by interweaving the waist strap webbing through proper places in the weight pockets 3 With the use of bolts supplied with the p...

Страница 8: ...pe of suit you use Together with GHOST system you can use the following types of trim pockets Standard trim pockets placed on straps to attach the tank or on additional strap of equal type placed anyw...

Страница 9: ...oviding optimal trim and stability NextGEN harness is traditionally equipped with V type crotch strap which distributes pressure on a larger area and at the same time improves comfort in particular wh...

Страница 10: ...the waist strap shall be fastened so that it is placed onto shoulder straps The fastening of the waist strap should press the shoulders straps to the body improving the adjustment of the harness You...

Страница 11: ...llowing picture shows GHOST compensator optimally attached to aluminium 80cf tank commonly used in diving centres operating in warm water areas In order to help you find the perfect point where to att...

Страница 12: ...BC in a reliable and safe manner you should connect the webbing as indicated in the pictures below Before connecting the tank carefully wet the connecting straps Otherwise they may loosen and the tank...

Страница 13: ...ble as a result for shorter people to lower the diving tank and at the same time retain perfect trim and safe tank attachment The adapter and buoyancy compensator are mounted to the harness with the u...

Страница 14: ...nto the quick connector step 2 as presented in the pictures below LP hose connection using the 1 st stage of the regulator must be made to the low pressure LP port only Connection to the HP port may r...

Страница 15: ...atic dump valve is activated The automatic dump valve should open with a characteristic sound The air supply should stop immediately after release of the inflator button 5 Check the correctness of man...

Страница 16: ...cy you should press the inflator button for a short moment If more air needs to be added to the BC press the inflator button for a short moment several times During release of air from the BC hold the...

Страница 17: ...inse the BC inside press the purge button of the inflator and fill the BC approximately full with water by means of a garden hose spout or other source of fresh water Rotate the BC several times and n...

Страница 18: ...ugh identical by all appearances may have slightly different properties which may negatively affect the working life of the BC The only maintenance procedure which may be performed by the user is rins...

Страница 19: ...0 dTEX Mounting bolts displacement 11 cali 27 94 cm Dry weight without the harness 0 65 kg Inflator Type K type Working pressure range From 6 bar to 17 23 bar 250 PSI Permisible tank parameters Type S...

Страница 20: ...xDEEP Ul Ogrodnik w 3 43 227 G ra Polska Tel 48 12 44 66 998 e mail biuro xdeep pl...

Отзывы: