background image

7

NMS

450

X

STIMPOD

Intelli Cable Software: NMShow

Live View

The main components of the Live view are described below. Please note that this functionality works best with the Auto 
mode of the Stimpod NMS450X.

1. 

Device selection – This allows the user to select the NMS450X device to be linked from the list of  

 

 

 

devices connected to the PC. 

2. 

Refresh button – Click this to refresh the list of devices connected to the PC.

3. 

File name – An identifier to help the user distinguish this session from other sessions when using  

 

 

 

the archives.

4. 

Memo (optional) – Any general notes or additional information to attach to the session.

5. 

Record ID (optional) – A internal record to which this session should be linked.

6. 

Date of birth (optional) – Date of birth of the patient.

7. 

Height (optional) – The height of the patient can be entered here, either in centimeters or in feet and 

 

 

 

inches. The centimeter field will automatically update from the feet and inches and vice versa. 

8. 

Weight (optional) – The weight of the patient.

9. 

Gender (optional) – Insert patient’s gender.

10. 

Class (optional) – The patient’s ASA (American Society of Anesthetists) physical status classification.

11. 

Create button – When a device has been selected and a file name has been entered, and the user is satisfied    

 

with the information captured in the optional fields, clicking this button will create the session and open the Live    

 

data view screen.

12. 

Back Button - This button will clear all fields and return to the Activity selection screen.

Содержание STIMPOD NMS 450X

Страница 1: ...Intelli Cable Software NMS 450X STIMPOD NMShow XM400 201A04 v1 0...

Страница 2: ...NMS 450X STIMPOD Intelli Cable Software NMShow...

Страница 3: ...n 5 Creating a New Session 6 Live View 7 Stimpod Status 9 Tab Controls 10 Stimulation Details 10 Contents Zoom Controls 10 Main Display Area 11 Profile Graph 11 Pulse Data Graph 13 Stimulation Data Ta...

Страница 4: ...connect to the internet to determine whether an update is available If an update is available it will be downloaded in the background and installed when the application is closed When the application...

Страница 5: ...into the FireWire port of the Stimpod Step 02 Plug the NMT Monitoring cable into the FireWire port of the Intelli cable Step 03 Plug the USB cable from the Intelli cable into the PC FireWire Cable NM...

Страница 6: ...o create a new user follow the steps below or see the instructions onscreen Firstly ensure that the Stimpod is on and the NMT Monitoring cable in inserted Navigate to the screen as shown in the pictur...

Страница 7: ...a password in the Password field The password should be at least 6 characters long Please be sure to keep the password in a safe place to ensure the user s data is secure as a password cannot be recov...

Страница 8: ...ing Live mode 1 Enter a username This is the unique identifier linking the user to the sessions recorded 2 Enter a password 3 Click the Login button If the correct username and password combination ha...

Страница 9: ...ed to the host device via the NMS450X Intelli cable Ensure that the NMT Monitoring cable is inserted Click on Live from the Activity selection screen to initiate a new session Several fields are avail...

Страница 10: ...A internal record to which this session should be linked 6 Date of birth optional Date of birth of the patient 7 Height optional The height of the patient can be entered here either in centimeters or...

Страница 11: ...NMS450X STIMPOD Intelli Cable Software NMShow 8 Closed Circuit Fig 7 1 2 3 4 5 7 8 6...

Страница 12: ...stimulation graph or the stimulation data table 6 Stimulation mode selector Select the stimulation mode for which to display details 7 Toolbar Start a new session add a comment or export data and more...

Страница 13: ...of the selected stimulation as is displayed on the Stimpod The third tab controlis the Data Table and displays the data for each stimulation in tabular format including a time stamp measured and set c...

Страница 14: ...ratios between 10 and 40 Moderate TOF counts between one and three are classified as a moderate block TOF counts of four with a ratio less than 10 technically constitutes the boundary between Shallow...

Страница 15: ...n 4 The result of a single stimulation in this case TOF 5 A depth of block zone 6 Commented stimulation sequences 7 Bar indicating the currently selected stimulation This will be the stimulation for w...

Страница 16: ...meter response in a similar way as on the Stimpod Stimulation Data Table The stimulation data table displays the stimulation results set and measured currents the depth of block zone stimulation mode...

Страница 17: ...om which the user can once again choose to use the Archive or start a new Live session 2 Comment Add a comment to the current stimulation See the Adding comments sub section below 3 Export CSV Export...

Страница 18: ...circles will display the comment text Fig 7 6 Alternatively previous comments will also be displayed on the Add Comment screen Custom comments can be added on the Add Comment screen by entering text...

Страница 19: ...add a new standard comment To edit a standard comment click the Edit link on the appropriate comment from the list This will populate the text area where it can be changed Remember to save after any c...

Страница 20: ...PDF A report can be generated from the session data including the captured session information statistics the profile graph comments and optionally all the stimulation data as on the data table Click...

Страница 21: ...The pause button This will prevent the stopwatch from counting up while keeping the current stopwatch value 6 The start button When clicked this will cause the stopwatch to continue counting up from t...

Страница 22: ...ts if a search keyword was typed in or all sessions Please note that only sessions linked to the current user will be displayed 4 Selected session Click on a session to select it The captured informat...

Страница 23: ...There is no live settings bar for the same reason as above 3 Only a simple clock is displayed i e no stopwatch and no session timer 4 Graphs and tables do not update since the archived session is stat...

Страница 24: ...g a New Session Window 06 Fig 7 Primary Session Window 08 Fig 7 1 Stimpod Status 09 Fig 7 2 Stimulation Details Bar 10 Fig 7 3 Profile Graph 12 Fig 7 4 Stimulation Selector 14 Fig 7 5 Toolbar 14 Fig 7...

Страница 25: ...NMS450X STIMPOD Intelli Cable Software NMShow 22 Notes...

Страница 26: ...NMS 450X STIMPOD Intelli Cable Software NMShow...

Отзывы: