Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0
147
Protection SHUTdown Sub-Register
Table 4.12
Protection SHUTdown Sub-Register
Remote CONtrol Sub-Register
This identifies which remote interface is controlling the unit. Only one bit is active
at a time with the exception of analog control, where voltage or current alone, or both
may be under remote control. Current share mode is considered to be under local
control, even though the user cannot adjust the voltage setting from the front panel.
Bit
Bit Weight Bit Name
Description
0
1
Over VOLTage
Over voltage protection has tripped
1
2
Under VOLTage
Under voltage protection has tripped
2
4
Over CURrent
Over current protection has tripped
3
8
Under CURrent
Under current protection has tripped
4
16
Over POWer
Over power protection has tripped
5
32
Under POWer
Under power protection has tripped
6
64
AC Off
AC Off protection has tripped
7
128
Over TEMPerature
Over temperature protection has tripped
8
256
SENSe
Sense protection has tripped
9
512
FOLDback
Foldback protection has tripped