Truecharge 10TB Owner’s Manual
12
2. Review any literature that was supplied with the batteries regarding
battery-specific charging requirements.
3. For “Flooded” batteries, top up the electrolyte level with distilled water.
4. Switch on AC power to the charger, and switch on the 15-amp breaker
installed in section 4.4. Also, switch on the power switch if this optional
item was installed.
5. The “Bulk” status light will switch on, indicating that the Truecharge
has begun charging in bulk charging mode.
6. Read section 5.0 to familiarize yourself with the various modes of
operation of the Truecharge as it brings the battery(s) up to full charge.