Table 2.10
Remote Mode Power On Conditions
Remote Mode
Operation
While in remote mode, use the interface commands to control the output of the
power supply from a computer. See Section 3 for a complete list of
device-dependent commands available with this interface.
From remote mode, change to local mode operation by pressing the front panel
LOCAL button or by sending either the GTL (Go to Local) command or the REN
(Remote Enable) OFF command. You can disable the LOCAL button by using the
LLO (Local Lockout) command. For an example of how to use Local Lockout, see
“Local Lockout (LLO) Command” on page 30.
To return to remote mode, ensure that the REN command is set to ON and then
send any valid device-dependent command. Since the remote mode output settings
may be different from the local mode settings, the output is programmed to protect
the load by turning off when you toggle from local to remote mode during a
session. Check your remote settings and then send OUT ON to restore the output.
Condition
Default Settings
7.5-140 Model Example
Voltage
0 V
VSET 0
Current
0 A
ISET 0
Soft Voltage Limit
VMAX (see models)
VMAX 7.5
Soft Current Limit
IMAX (see models)
IMAX 140
OVP Trip Voltage
Model VMAX + 10%
OVSET 8.25
Delay
0.5 s
DLY 0.5S
Remote Enable
ON
REN ON
Foldback Protection
OFF
FOLD OFF
Output
ON
OUT ON
Hold
OFF
HOLD OFF
Unmask
NONE
UNMASK NONE
AUXA
OFF
AUXA OFF
AUXB
OFF
AUXB OFF
Содержание RS232-XHR