Installation and Configuration
Initial Inspection
22
Operating Manual for GPIB for XHR/XFR Series Power Supply
Figure 2.3
GPIB Interface PCB
JUMPER SELECTION
J65
Local OVP control selection
[closed] [default]. See page 28.
[open] Front Panel OVP Control.
J93
User TTL shutdown (S/D) selection
[1-2] User TTL S/D line active low.
See page 31.
[2-3] [default] User TTL S/D line active high.
J103
Remote OVP Control Selection
[closed] [default]. See page 28.
[open]
Note: All other jumpers are not user-selectable.
LED INDICATORS
CR89
Red Diagnostic LED
Bus error or soft restart on Slave circuitry.
CR166
Red Diagnostic LED
Soft restart on Master circuitry.
CR167
Green Diagnostic LED
Bus error on Master circuitry.
See page 52.
EPROMS
U117
Slave EPROM
See revision number stamped on EPROM.
U191
Master EPROM
See revision number stamped on EPROM.