975-0754-01-01
15
Operating in Inverter Mode
Status LED During Inverter Operation
The following summarizes the behavior of the Status LED during
Inverter operation.
Table 2
Status LED during Inverter Operation
Status
LED
Display
Screen
Condition
Solid
YELLOW
.
(where 12.8 is
an example of
battery
voltage)
Select button is pressed to display Input
Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.
(where 11 is
an example of
current)
Select button is pressed to display Input
Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.
.
(where 0.85 is
an example of
output power
in Kilowatts)
Select button is pressed to display Output
Power.
The Output Power LED lights up.
Value in display screen is shown as
Kilowatts.
Solid RED
through
Fault condition detected and AC output
power is not available. For details, see
Table 3, “Error Codes Displayed on the
Display Panel Screen” on page 24.
through
Warning condition detected while AC
output power is still available.
See Table 3, “Error Codes Displayed on the
Display Panel Screen” on page 24.
Off
Off
Inverter operation is OFF.
Off (or
Yellow)
.
No communication between the Freedom
Xi and the Display Panel because the
battery voltage was too low to start the
Inverter.
Table 2
Status LED during Inverter Operation
Status
LED
Display
Screen
Condition
Freedom XI Owners Guide.book Page 15 Friday, September 18, 2015 2:57 PM
Содержание Freedom Xi 1000
Страница 2: ...Freedom XI Owners Guide book Page ii Friday September 18 2015 2 57 PM ...
Страница 12: ...Freedom XI Owners Guide book Page x Friday September 18 2015 2 57 PM ...
Страница 14: ...Freedom XI Owners Guide book Page ii Friday September 18 2015 2 57 PM ...
Страница 36: ...Freedom XI Owners Guide book Page 22 Friday September 18 2015 2 57 PM ...
Страница 47: ...Freedom XI Owners Guide book Page i Friday September 18 2015 2 57 PM ...