Basic Installation Procedures
975-0821-01-01
29
WARNING
ELECTRIC SHOCK HAZARD
Use a screwdriver to loosen the captive nut panel screw.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Figure 9 Loosening the captive nut panel screw
1
1
Captive nut panel screw
4. Strip a single AC input wire, as appropriate. Strip 10 mm off
the ends of each of the three the wires (tin the exposed
copper wire with lead-free solder using a soldering iron).
5. Remove the knockout and install PG16 (or PG21) strain
relief clamp.
6. Route the wires through the strain relief clamp (not shown in
the figure).
Figure 10 Routing the AC input wires
N
L
G
N
L
G
N
L
G
2
1
3
4
5
1
step 8a
2
step 8b
3
step 8c
4
15mm
5
to circuit breaker
NOTE
: AC input hole - install a strain relief clamp (not shown).
7. Locate the Neutral, Earth and Line terminals on the AC input
terminal labeled as
N
,
G
, and
L
respectively.