Basic Installation Procedures
975-0821-01-01
33
Step 5: Connecting AC Output to an
Existing AC Circuit
WARNING
ELECTRIC SHOCK AND FIRE HAZARDS
n
Make sure wiring is disconnected from all electrical sources
before handling. All wiring must be done in accordance with
local and national electrical wiring codes.
n
A manufacturer-tested and approved RCBO (Type B) must
be connected to the Freedom XC AC output and RCBO
protection must be provided on every receptacle connected
to the AC hard wired installation, if local regulations require
it.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
NOTICE
EQUIPMENT DAMAGE
n
Do not connect any AC source (such as a generator or
utility power) to the
AC output wiring
of the Freedom
XC.
n
The Freedom XC will not operate if its output is connected
to AC voltage from another source, and potentially
hazardous or damaging conditions may occur. These
conditions can occur even if the inverter/charger is off.
Failure to follow these instructions can result in equipment
damage.
Do not connect the Freedom XC to an AC branch circuit that has
high-power consumption loads.
The Freedom XC will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than
its rated output wattage.
Содержание Freedom XC 2000
Страница 1: ...Freedom XC 2000 230VAC Inverter Charger Owner s Guide Freedom XC 2000 230VAC 817 2080 12...
Страница 20: ...This page is intentionally left blank 2...
Страница 28: ...This page is intentionally left blank 2...
Страница 32: ...This page is intentionally left blank 2...
Страница 98: ...This page is intentionally left blank 2...
Страница 103: ...This page is intentionally left blank 2...