Operating Limits
975-0767-01-01
79
High Surge Loads
Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
Freedom X 1200 may not be able to start some of these motors
even though their rated steady state current draw is within the
inverter’s limits. The unit will shut down and indicate an overload
shutdown.
Over-temperature Conditions
During inverter operation, when the Freedom X 1200’s internal
temperature starts to approach its preset shutdown limit, the
display will show error code
E07
. If the over-temperature condition
persists, the display will show error code
E04
. The Status LED
turns solid RED and the inverter will shut down to prevent damage
to the inverter and protect the battery from being over-discharged.
However, when the internal temperature drops and falls within
normal operating temperature, the Freedom X 1200 will recover
automatically and will continue inverting.