AC/DC and GFCI Panel
20
Freedom X 1200 Owner's Guide
AC/DC and GFCI Panel
6
3
2
1
7
13
12
11
14
10
8
9
4
5
11
Figure 2 AC/DC and GFCI Panel
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
5 in-lb (0.56 N-m) torque of force to ensure a proper ground
connection and a required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Item
Description
1
ACC input terminal
for connecting ignition control wiring.
2
The
GFCI cover
is removed when installing the customer-
supplied GFCI receptacle (not included) is installed.
3
Captive nut panel screw
holds the wiring compartment
cover in place. See WARNING above.
4
Display panel.
See succeeding pages for a description.
5
Grounding lug
provides a ground path for the Freedom X
1200 chassis to the DC system ground. See WARNING.
6
AC input terminal opening
for routing AC input wiring.
7
AC output terminal opening
for routing AC output wiring.
Table 1 AC/DC and GFCI Panel Features