Inverter Applications
48
Freedom EX 4000 Owner's Guide
Problem Loads
Very Small Loads
If the power consumed by a device is less
than the 50-watt threshold, the Freedom EX
4000 will not run. When the Freedom EX
4000 is load sensing the output for loads,
lights that have a wattage lower than 50-watt
threshold, may flash momentarily.
Fluorescent
Lights and Power
Supplies
Some devices cannot be detected when load
sensing. Small fluorescent lights are the
most common example. Some computers
and sophisticated electronics have power
supplies that do not present a load until line
voltage is available. When this occurs, each
unit waits for the other to begin. To drive
these loads, either a small companion load
like a light bulb rated for more than 50 W
must be used to bring the Freedom EX 4000
out of search mode, or the Freedom EX 4000
may be programmed to remain on by
disabling search mode.
Clocks
You may notice that your clocks are not
accurate. Some of the clocks on your
appliances may reset when the Freedom EX
4000 is in search mode.