Basic Installation Procedures
975-0998-01-01
29
Parallel Stacking
A parallel stacking configuration allows the inverter and charger capacity of a system to be doubled. Parallel-stacked
inverter/chargers can operate from different battery banks, meaning each unit is connected to its own battery bank. However, it is
highly recommended to only use a single battery bank similar to series stacking. See
NOTICE
GENERAL PRECAUTIONS
n
Contact Xantrex prior to stacking two Freedom EX 4000 units together. Stacking configuration via USB is a required step to
enable stacking.
n
Install stacked Freedom EX 4000s in close proximity to each other.
n
Connect RJ45 CAT5e/6 straight-through network cables to each inverter’s Sync port as well as the RV-C ports shown in
below.
n
Do not connect any wires to the
AC IN L2
|
AC OUT L2
terminals on both units at all when stacking.
n
Each inverter must be enabled and turned on individually before AC power becomes available.
Failure to follow these instructions can result in equipment damage and may void the warranty.
Figure 15 RJ45 CAT5e/6 network cable for parallel stacking
A
B
C
D
c
Do not connect any wires to the
AC INPUT L2
terminals on both units at all when stacking.
A
First Freedom EX 4000
C
Second Freedom EX 4000
B
RJ45 CAT5e/6 network cable connected
to the Sync ports of each Freedom EX
4000
D
RJ45 CAT5e/6 network cable connected to the
RV-C ports of each Freedom EX 4000
including the network terminators.
Line and Neutral Wiring for Parallel Stacked Inverters
AC IN L2
terminals on both units must not be connected at all. Also for parallel stacking configuration, only
AC IN L1
|
AC OUT
L1
terminals should be used and that the
AC IN L2
|
AC OUT L2
terminals must have no connections at all. If
L2
is connected to
any incoming or outgoing AC line, the inverter/charger may suffer internal damage not covered by warranty.
In a stacked pair configuration, connect the two AC input neutrals together at the main distribution panel (SOURCE) and the two
AC output neutrals at an isolated neutral location in the inverter AC distribution sub-panel (INVERTER LOAD).