Xantrex APG-HPD Скачать руководство пользователя страница 24

Section 3. Operation

Readback and Status Indicators

22 

Operating Manual for APG for XT/HPD Series Power Supply

Readback and Status Indicators

Voltage and

Current

Readback

Voltage Readback

Connect a meter between J5 connector pin 19 (voltage readback) and either pin 

4 or 5 (program return).

Range:

  0-10V = 0-100% full rated voltage output of power supply

Current Readback 

Connect a meter between J5 connector pin 18 (current readback) and either pin 

4 or 5 (program return).

Range:

  0-10V = 0-100% full rated current output of power supply

Note:

The voltage and current readback signals have adjustable offset and range.  

These adjustments are accessible from the top of the power supply (see Figure 2.3, 
pg. 17).  The adjustments are independent of other power supply calibrations or 
adjustments such that APG readback can be zero and range calibrated without 
affecting other power supply parameters.

Operating

Mode Status

Connect voltmeter between J5 connector pin 9 (voltage/current limit mode 

indicator) and pin 6 (auxiliary ground).

Voltage Mode: 

active low open collector

Current Mode:

 high impedance open collector

Remote

Programming

Status

Remote programming status is available via J5 connector pins 7 (remote voltage 
program select) and 8 (remote current program select).  Reference to J5 connector at 
either pin 4 or 5 (program return).

J5-7 LOW = Remote Voltage Program, HIGH=Local Front Panel Control

J5-8 LOW = Remote Current Program, HIGH=Local Front Panel Control

Output Fail

Flag

The Output Fail Flag (J5 connector pin 21) signal is HIGH (open collector) when any 
one of the following conditions is true:

AC input to the power supply is below operating limits.

Over voltage protection is activated.

TTL shutdown is active.

Sense line protect circuit is active (excessive load line drop or load line(s) not 

connected or fuse(s) in power supply blown).

Содержание APG-HPD

Страница 1: ...Operating Manual Internal APG Analog Programming Interface for XT HPD Series Programmable DC Power Supply APG XT APG HPD...

Страница 2: ......

Страница 3: ...Operating Manual for Internal APG Analog Programming Interface for XT 60 Watt and HPD 300 Watt Series Programmable DC Power Supply...

Страница 4: ...right to use parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original War...

Страница 5: ...e product exchanged under warranty What does this warranty not cover This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal installation or troublesho...

Страница 6: ...T WILL XANTREX BE LIABLE FOR ANY SPECIAL DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECON...

Страница 7: ...ur product user manual for limitations on uses of the product Specifically please note that this power supply is not intended for use in connection with life support systems and Xantrex makes no warra...

Страница 8: ...High energy levels can be stored at the output voltage terminals on a power supply in normal operation In addition potentially lethal voltages exist in the power circuit and on the output and sense co...

Страница 9: ...of input and output power as well as the observance of safe techniques while effecting supply or pin connections and any changes in switch settings Refer to your power supply manual for installation c...

Страница 10: ...About This Manual viii Operating Manual for APG for XT HPD Series Power Supply...

Страница 11: ...tment 17 Section 3 Operation Remote Programming 19 Programming Output Voltage with a 0 10Vdc Voltage Source 19 Programming Output Voltage with a 0 10k Resistance 20 Programming Output Current with a 0...

Страница 12: ...Contents x Operating Manual for APG for XT HPD Series Power Supply...

Страница 13: ...programming of output voltage and or current limit using an available 10V reference 10mA max source 0 10V readback of output voltage and current with externally adjustable offset and range Status sig...

Страница 14: ...Section 1 Features and Specifications Specifications 12 Operating Manual for APG for XT HPD Series Power Supply...

Страница 15: ...ill be identified in the supply s documentation Inspect the unit for any signs of physical damage such as scratches cracks or broken switches connectors or displays Check the printed circuit board and...

Страница 16: ...dicated in this section The front panel LEDs indicate when V or I programming is selected PGM when TTL shutdown has occurred S D and when the supply exceeds the voltage trip point OVP You can adjust t...

Страница 17: ...aults Table 2 1 Rear Panel Switch S1 Default Settings Default Local control all switches OPEN Setting Function S1 1 TTL Shutdown Logic Select OPEN negative logic CLOSED positive logic S1 2 Resistive C...

Страница 18: ...hassis via one of the J5 connector screws Note In order to maintain isolation of power supply output any programming source must also be an isolated source J5 Connector Pin Assignments Table 2 2 J5 Co...

Страница 19: ...ration Adjustment You can access most calibration potentiometers through the top of the unit see Figure 2 3 The exceptions are Voltage Program OFFSET and RANGE which are on the unit s rear panel which...

Страница 20: ...Section 2 Installation and Configuration Calibration Adjustment 18 Operating Manual for APG for XT HPD Series Power Supply...

Страница 21: ...ct to the ON closed position Or connect J5 pin 7 remote voltage program select to J5 pin 6 auxiliary ground As these two control functions are wired in parallel they function as a logic OR 2 Connect t...

Страница 22: ...osed position 3 Connect a variable resistor between pin 17 voltage program and either pin 4 or pin 5 program return 4 Adjust the resistance from 0 10k to vary the power supply output from 0 100 of rat...

Страница 23: ...tput You may set the power supply s output voltage using another source or the front panel voltage control Programming with a Fixed 10V Reference The APG Interface J5 connector provides a 10 V referen...

Страница 24: ...o and range calibrated without affecting other power supply parameters Operating Mode Status Connect voltmeter between J5 connector pin 9 voltage current limit mode indicator and pin 6 auxiliary groun...

Страница 25: ...ting the OVP Trip Level 1 Turn the power supply OFF 2 Insert a small flat bladed screwdriver through the OVP ADJ OVP Adjust hole in the front panel to turn the adjusting screw fully clockwise one turn...

Страница 26: ...t panel LED comes on Connect the signal source between J5 connector pins 15 TTL shutdown positive and 2 TTL shutdown return negative Set rear panel switch S1 1 TTL shutdown to ON closed to obtain posi...

Страница 27: ...tes 1 Master slave power supplies must have the same output ratings 2 Set switch S2 on the slave unit s APG Interface PCB to the correct model number factory preset This requires that you remove the p...

Страница 28: ...Section 3 Operation Tracking 26 Operating Manual for APG for XT HPD Series Power Supply...

Страница 29: ......

Страница 30: ...echnology Inc 8999 Nelson Way Burnaby British Columbia Canada V5A 4B5 604 422 8595 Tel 604 421 3056 Fax 800 667 8422 Toll Free North America prg info xantrex com www xantrex com TM 5A6H 01XN PRINTED I...

Отзывы: