GLOSSARY

AGS (Automatic Generator Start Control System) 

A control system to

automatically start the auxiliary generator in response to a low battery
and/or cooling/heating demand.

AGS Controller 

The part of the AGS Control System that connects to the

wiring of the coach. It contains a micro-controller and a real-time clock.

AGS Remote Panel 

The user interface part of the Automatic Generator

Start Control System. It connects to the Control Module through the data
cable.

AUTO MODE

 In this mode the AGS will automatically start the generator

as required by a low battery or a requirement for heating/cooling.

AUTO QUIET MODE

 In this mode is the same as AUTO mode, except

the AGS will not start the generator during quiet hours.

Battery Sense 

This is the input to the AGS control module used to

determine if the battery is low. This battery sense voltage may or may not
be the same battery supplying the power to the AGS control module.

Data cable 

 A six-pin telephone-style cable used to carry power and data

between the Remote and the Control Module.

Ground 

The reference potential of a circuit. In automotive use, the result

of attaching one battery cable to the body or frame which is used as a
path for completing a circuit in lieu of a direct wire from a component.

Negative 

Designating or pertaining to a lower electrical potential.

Positive 

Designating or pertaining to electrical potential; opposite of

negative. The positive battery terminal.

QUIET TIME 

The period of time that the AGS is prohibited from starting

the auxiliary generator regardless of battery condition or demands for
heating/cooling. The AGS is in this mode when the QUIET TIME light is
blinking.

Thermostat 

 The heat/cooling thermostat.

Volt 

Short for voltage, the unit of measure for electric potential.

VDC 

Direct current voltage.

Содержание AGS

Страница 1: ...Xantrex Automatic Generator Start Control System AGS Owner s Manual...

Страница 2: ...CH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision October 2002 Revision 1 Part Number 445 0190 01 01 Contact Information Web www xantrex com Email Cu...

Страница 3: ...he generator at inconvenient times SAFETY SUMMARY General safety information for installation and operation is contained throughout this manual where it applies and is not completely included in this...

Страница 4: ...time setting A TIME ZONE indicator is pro vided for easy changing of local time when travelling Displays generator status The Remote Panel indicates if the generator is on GEN ON and if the generator...

Страница 5: ...r at the appropriate time If the generator stops for some other reason even if it is turned Off by a manual switch other than the AGS the AGS system will assume that there is a FAULT It will turn itse...

Страница 6: ...GS will not respond to requests for low battery or thermostats starting because the Local Time is within the Quiet Time window ON OFF MODE Switch Pressing the ON OFF switch changes the status of the A...

Страница 7: ...REQUIRED Use the SELECT switch to select LOCAL TIME Press the TIME ZONE switch to select the time zone Press the SET TIME switch to set the local time hour Quiet Time BEGIN REQUIRED SETTING Use the S...

Страница 8: ...75 W X 3 75 H X 0 65 D Use the supplied template to cut the proper size hole Mount the Remote Panel unit using the screws supplied Route the control cable from the AGS Remote Panel to the Con trol Mod...

Страница 9: ...DC ON 8 PREHEAT Contact for generator preheat signal 9 START COMMON Generator Start signal contact Typi cally connect to generator ground 10 STOP COMMON Generator Stop signal contact Typically connect...

Страница 10: ...n This may be done by removing power from the AGS Controller To accomplish this the AGS Controller should be interlocked with the ignition switch to control the POSITIVE POWER 5 or with the parking br...

Страница 11: ...DATA CABLE 4 CONDUCTOR SUPPLIED AGS CONTROLLER AGS REMOTE PANEL 11...

Страница 12: ...diately The action from the buttons on the Remote Panel is delayed to ensure that action is required How long is the delay from request for thermostat request to generator start The time delay is 60 s...

Страница 13: ...VDC at AGS Controller wires 5 and 13 Verify that the Generator Hour Meter Signal wire 3 is connected to the AGS Control Module Verify Battery Sense Positive wire 12 connection Check the preheat if req...

Страница 14: ...mine if the battery is low This battery sense voltage may or may not be the same battery supplying the power to the AGS control module Data cable A six pin telephone style cable used to carry power an...

Страница 15: ...rs both parts and labor necessary to repair the product and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska a...

Страница 16: ...TION WITH YOUR XANTREX PRODUCT AND IS WHERE PERMITTED BY LAW IN LIEU OF ALL OTHER WARRANTIES CONDITIONS GUARANTEES REPRESENTATIONS OBLIGATIONS AND LIABILITIES EXPRESS OR IMPLIED STATUTORY OR OTHERWISE...

Страница 17: ...antrex makes no warranty or representation in connection with any use of the product for such purposes Return Material Authorization Policy Before returning a product directly to Xantrex you must obta...

Страница 18: ...number where you can be reached during work hours A brief description of the problem 3 Ship the unit prepaid to the address provided by your Xantrex customer service representative If you are returni...

Страница 19: ...three items MECHANICAL Controller Size 6 57 W X 4 25 H X 1 875 D Remote Panel Size 5 75 W X 3 75 H X 0 93 D Remote Panel Cutout size 4 875 W X 2 875 H Weight Controller 1 lb 12 oz Remote Panel 3 oz E...

Страница 20: ...Xantrex Technology Inc Toll free 1 800 670 0707 Direct 1 604 422 2777 Fax 1 604 420 2145 CustomerService xantrex com www xantrex com 445 0190 01 01 Rev 1 Printed in the U S A...

Отзывы: