Basic Installation Procedures
975-0822-01-01
35
Description of Ignition Control Features
For information about the features and instructions on changing
the ignition control features, see
.
Ignition Auto-
on (
ATO
)
This setting allows the inverter to operate
(Battery mode) automatically when an
ignition control wire is connected to the
ACC input and a valid ignition signal is
constantly detected. The inverter works in
tandem with the vehicle’s ignition circuit.
Ignition Lock-
out (
LOt
)
This setting allows the inverter to operate
(Battery mode) when an ignition control
wire is connected to the ACC input
terminal and a valid ignition signal is
constantly detected.
When enabled, you have to manually
press the Power button on the display
panel to operate the inverter.
Off (
OFF
)
To completely disable the ignition control
features do the following:
Set Ignition Control to Off (
OFF
) using the
Select buttons on the Display panel.
Table 9 Ignition Control Features
Connecting to the Remote Port
The Freedom X can accommodate the Freedom X Remote Panel
with cable (PN: 808-0817-01) (sold separately; comes with 7.6m-
cable) or the Freedom X Remote Panel unit (PN: 808-0817) (sold
separately; unit only without cable).
To connect the remote panel to the remote port:
n
Plug the remote panel unit's cable connector to the RJ12
Remote port on the unit.
NOTE
: When the remote panel is connected, turn the inverter’s
Power button to to Standby (up position). This allows the remote
panel to control the inverter’s power status.
Содержание 817-2000-12
Страница 1: ...Freedom X 2000 230V Inverter Owner s Guide Freedom X 2000 230V 817 2000 12 ...
Страница 12: ...This page is intentionally left blank 2 ...
Страница 24: ...This page is intentionally left blank 2 ...
Страница 52: ...This page is intentionally left blank 2 ...
Страница 77: ...This page is intentionally left blank 2 ...
Страница 91: ...This page is intentionally left blank 2 ...