Basic Installation Procedures
975-0822-01-01
21
Connecting the Equipment Earth
WARNING
ELECTRIC SHOCK HAZARD
Never operate the Freedom X without properly connecting the
equipment earth. A shock and energy hazard could result from
improper earthing.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
The Freedom X has an earth lug on the side of the unit as shown in
Connecting the Equipment Earth
. Follow the guidelines in
to connect the inverter’s chassis to
earth.
Figure 8 DC Panel Connections
1
1
DC earthing lug
Earthing Locations
You must connect the equipment earth lug to an earthing point—
usually the vehicle’s chassis or DC negative bus earth—using
recommended copper wire (if insulated then green insulation with
or without one or more yellow stripes) or larger.
Make sure to tighten the bolt on the DC earth lug to a torque of
2.6 N-m of force. Apply an anti-corrosion compound to the copper
wire prior to connecting to the DC earth lug.
For recommended equipment earth cable size, see below.
Application
Minimum equipment cable size
(Stranded copper cable is required)
Recreational
Vehicle
10mm
2
Marine
55mm
2
NOTE
: There are no restrictions on length for the equipment
earth cable but try to make it as short as practical to a secure
chassis connection. In general, the equipment earth cable size
must not be smaller than one size than the supply cable.
Table 6 Equipment DC earth cable size
Содержание 817-2000-12
Страница 1: ...Freedom X 2000 230V Inverter Owner s Guide Freedom X 2000 230V 817 2000 12 ...
Страница 12: ...This page is intentionally left blank 2 ...
Страница 24: ...This page is intentionally left blank 2 ...
Страница 52: ...This page is intentionally left blank 2 ...
Страница 77: ...This page is intentionally left blank 2 ...
Страница 91: ...This page is intentionally left blank 2 ...