14
Freedom XC Owner’s Guide
Basic Installation Procedures
AC Distribution Panels
Most systems incorporate distribution centers both ahead of the
Freedom XC (the AC source panel) and between the Freedom XC
and the loads (the AC load panel). An AC source panel includes a
main circuit breaker, which serves as over-current protection and as
a disconnect for the AC shore power supply line. Additional circuit
breakers serve individual circuits, one of which serves the Freedom
XC. The AC load panel can incorporate an AC output circuit
breaker and breakers for individual load circuits.
AC Cabling
AC cabling includes all the wires and connectors between the AC
source and the Freedom XC, as well as all cabling between the
Freedom XC and the AC output panels, circuit breakers, and loads.
The type and size of the wiring varies with the installation and load.
For example, in high vibration environments, such as marine or RV
applications, wire nuts may not be acceptable, so crimp splices
would be required. In other applications, flexible multiple-strand
wire may be required. Installation codes usually specify solid or
stranded, overall size of the conductors, and type and temperature
rating of the insulation around the wire.
AC breakers and fuses must be sized to adequately protect the
wiring that is installed on the input and output AC circuits of the
Freedom XC. All breakers and wiring must be sized and connected
in accordance with the electrical codes or regulations applicable to
your installation. Table 1 gives some examples of wiring sizes based
on the U.S. National Electrical Code and the Canadian Electrical
Code. These examples are based on using a two-conductor-plus-
ground cable rated at 75
°
C, and assuming an ambient temperature
of up to 30
°
C. Ensure that your breakers and fuses have suitable
temperature ratings for your wiring. Other codes and regulations
may also be applicable to your installation.
Table 1
Required AC Wire Size vs Breaker Rating
Breaker Size (amps)
10A
15A
20A
30A
Minimum Wire Size
14AWG
14AWG
12AWG
10AWG
NOTICE
RISK OF DAMAGE TO THE INVERTER
Do not connect the Freedom XC to a 120/240V, 3-pole, 4-wire circuit.
Failure to follow these instructions can damage the unit and/or equipment.
Freedom XC Series INV-CHG Owners Guide.book Page 14 Wednesday, June 7, 2017 3:13 PM
Содержание 817-1050
Страница 2: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Страница 12: ...Freedom XC Series INV CHG Owners Guide book Page x Wednesday June 7 2017 3 13 PM...
Страница 14: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Страница 22: ...Freedom XC Series INV CHG Owners Guide book Page 8 Wednesday June 7 2017 3 13 PM...
Страница 52: ...Freedom XC Series INV CHG Owners Guide book Page 38 Wednesday June 7 2017 3 13 PM...
Страница 76: ...Freedom XC Series INV CHG Owners Guide book Page 62 Wednesday June 7 2017 3 13 PM...
Страница 88: ...Freedom XC Series INV CHG Owners Guide book Page 74 Wednesday June 7 2017 3 13 PM...
Страница 89: ...Freedom XC Series INV CHG Owners Guide book Page i Wednesday June 7 2017 3 13 PM...