40
Freedom SW 230V Installation Guide
Installing the Inverter/Charger
Step 7: Performing Checks Prior to Initial Start-Up
Before testing your installation, ensure these conditions are
met:
❐
Chassis and AC grounds are properly installed
❐
AC input connections and AC output connections are
wired correctly on the terminal block and not reversed
❐
Positive (+) battery cable is connected to the positive (+)
battery terminal through the DC fuse and disconnect
switch or DC circuit breaker
❐
Negative (–) battery cable is connected to the negative (–)
battery terminal
❐
Battery voltage is within the proper range of 20–32 volts
DC
❐
DC disconnect switch or breaker is turned off
❐
AC input and output breakers are turned off
❐
All connections are tight