Example 1

Four Smart Pad

2

’s (with Status), five 780-80’s (with Status), two PA640’s and one 599 Pulsed Switching

Module are used.  Add up the currents: (4 x 90 mA) + (5 x 30 mA) + (2 x 11 mA) + (1 x 11 mA) = 543 mA
total.  This is well within the 

1.8 A

 (1800 mA) limit.  Therefore, no external power supply is needed.

Example 2

24 Smart Pad

2

’s (4 per zone, with Status), twelve 780-80’s (2 per zone, with Status), two PA640’s and one

599 Pulsed Switching Module are used.  Add up the currents: (24 x 90 mA)  + (12 x 30 mA) + (2 x 11 mA)
+ (1 x 11 mA) = 2553 mA  total current.   This exceeds the 

1.8 A

 limit by 753 mA.  Therefore, a 782-00 external

power supply is needed to power the extra Smart Pad

2

’s and IR receivers that cause the 

1.8 A 

limit to be

exceeded. In this case, you would have to power seven Smart Pad

2

’s and five 780-80 IR Receivers

externally (780 mA) to ease the load sufficiently.

Fig. 7  Using a CB18 to provide a +12V DC rail (if needed) to externally power extra keypads and IR receivers to prevent overload

of the internal power supply of the ZPR68-10.

ZONE  CONTROL - IR INPUTS

+12V

GND

STATUS

IR IN

9

8

6

7

4

5

2

3

1

ZPR68-10

Zone Control - IR Inputs section

120 V AC
(Unswitched)

782-00

Power Supply

Smart Pad

2 or 3

(Four shown)

780-80

"J" Box

IR Receivers
(Five shown)

V

IR

ST

G

V

IR

ST

G

V

IR

ST

G

V

IR

ST

G

V

IR

ST

G

+12V

(white

striped

side)

GND

GND

+12V

V

IR

ST

G

V

IR

ST

G

V

IR

ST

G

V

IR

ST

G

V = +12V

IR = IR Signal
ST = Status
G = GND

CB18

"The Strip-IR"

Connecting Block

Fig. 7 illustrates how you can do this by using a CB18 "Strip-IR" Parallel Connecting Block to provide a
separate +12V DC rail.  This powers the additional IR receivers and keypads independent of the +12V of
the ZPR68-10.

NOTE:  The 782-00 Power Supply has a capacity of 1000 mA.  If you have a system that is so extensive
that the total current exceeds the 1.8 A limit of the ZPR68-10 by more than 1000 mA, use two 782-00's
connected so that two se12V DC rails are created.  Connect two groups of the extra devices so
that the total excess load is shared equally between the two 782-00's.

CAUTION:  To prevent current "hogging" and power supply shutdown, never connect a 782-00 in parallel
with the +12V terminal of the ZPR68-10 or in parallel with another 782-00!

ZPR68-10

Содержание ZPR68-10

Страница 1: ...audio source can be trimmed by the installer to prevent large volume differences when switching between sources A COM PORT using a female DB9 connector allows full control and status operations with...

Страница 2: ...3 ZPR68 10 Panel Features and Functions 1 COMMON IR LEVEL DIP Switches These DIP switches set the output power level to HI or LO for emitters connected to the COMMON IR OUTPUT jacks See item 4 under I...

Страница 3: ...ower is applied to the ZPR68 10 It stays on continuously even when all zones are turned off as long as AC power is applied to the plug in power supply 13 COM PORT This DB9 female connector permits 2 w...

Страница 4: ...L The RC68 and the RC68 programmer available separately contains all the commands necessary to set up and operate the ZPR68 10 In addition you will need it to program the universal learning devices ac...

Страница 5: ...l flat E FLAT Refer to ZONE ADJUSTMENTS procedure 13 E FLAT button Switches the tone settings to electrical flat flat frequency response and the balance to center from customized settings In conjuncti...

Страница 6: ...The common CO terminal provides AC power ON OFF management for the PA640 s and for the common sources through GATEKEEP IRTM Note All source components in this typical system must have their ON OFF fun...

Страница 7: ...TOR TV MONITOR SOURCE COMPONENTS L R A V Patch Cords A V Patch Cords ZONE AMPLIFIERS MODEL PA640 2 Remote ON OFF Remote ON OFF RF IN RF IN VIDEO IN TV MONITOR VIDEO IN ANT or Cable 4 Conductor Home Ru...

Страница 8: ...40 Power Amplifiers and to the and terminals of the GMM1A Module of the GATEKEEP IR You may use two of the Xantech part 6015900 five foot 2 conductor cables 3 5mm mini plug on one end and stripped tin...

Страница 9: ...ations However if you have a system where the total current demand does exceed 1 8 A then an external power supply s must be used to power the extra devices to prevent overheating and shutdown of the...

Страница 10: ...pply of the ZPR68 10 ZONE CONTROL IR INPUTS 12V GND STATUS IR IN 9 8 6 7 4 5 2 3 1 ZPR68 10 Zone Control IR Inputs section 120 V AC Unswitched 782 00 Power Supply Smart Pad2 or 3 Four shown 780 80 J B...

Страница 11: ...urces to sound equally loud when switching from one to another 1 Select the input that has the lowest apparent volume level from any zone 2 Press TRIM button This activates the TRIM mode Note TRIM mod...

Страница 12: ...omplete the next step is to program the Xantech SmartPads and or learning remotes such as Xantech s URC s with the needed GATEKEEP IR ZPR68 10 and the source component commands for system operation fr...

Страница 13: ...ns If an AC power line failure occurs proceed as follows after power is restored 1 Press an INPUT source button to turn any zone ON 2 Adjust VOLUME and other functions as outlined under Zone Operatiao...

Страница 14: ...her zone s as well Zone to zone IR cross talk The IR output from the emitters connected to the Common IR Outputs attached to the common components e g tape VCR tuner etc may be radiating into the IR s...

Страница 15: ...and GND on each of the offending zones Refer to Fig 7 under INSTALLATION section for details The capacitance of the shielded cable prevents high bit rate commands from passing through unaltered The r...

Страница 16: ...s Audio L R Zone Outputs Video Treble Bass LMC1982 LPF Level Volume Balance X1 X0 5 X 2 X 2 Buffer Buffer Buffer Buffer Video Gain Adjust Jumper 0 dB 3 dB Common IR Level LO H I IR Confirm CO G Zone I...

Отзывы: