XT-SW41-4K18G
USER MANUAL
www.xantech.com
®
The XT-SW41-4K18G switch can be controlled via a 9-pin serial cable.
Details of RS-232 pin assignment and communication are below. Please note that depending on your control device serial port pin configuration
you may require either a ‘Straight’ RS-232 cable or ‘Null-modem’ type.
XANTECH RS-232
CONTROL SYSTEM
PIN
Assignment
PIN
Assignment
1
NC
1
NC
2
Tx
2
Rx
3
Rx
3
Tx
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
Baud Rate:
57600 bps
Data Bit:
8-bit
Parity:
None
Stop Bit:
1-bit
Flow Control:
None
Common Mistakes
• Carriage return – some programs do not require the carriage return where as other will not work unless sent directly after the string. In the
case of some Terminal software the token <CR> is used to execute a carriage return. Depending on the program you are using this token
maybe different. Some other examples that other control systems deploy include \r or 0D (in hex)
• Spaces – Blustream commands do not require space between commands unless specified. There may be some programs that require spacing
in order to work.
- How the string should look is as follows OUTFR03
- How the string may look if spaces are required: OUT{Space}FR{Space}03
• Baud rate or other serial protocol settings not correct - see above
RS-232 Settings
RS-232 COMMAND
DESCRIPTION
?
Print Help Information
HELP
Print Help Information
STATUS
Print System Status And Port Status
IRON/OFF
Set System IR Control On Or Off
KEYON/OFF
Set System KEY Control On Or Off
RESET
Reset System To Default Setting (Should Type “Yes” To Confirm, “No” To Discard)
OUTFRyy
Set OUTPUT From INPUT:yy
OUTON/OFF
Set OUTPUT Port On or Off
Example: OUTFR04 (This would switch the output to source input 4)
RS-232 Control