IR Input Jack

Zone A/V

Output Jacks

Video Gain

Adjustment Pins (PJ1)

Jumper

Zone PCB

Jumper

Shown in

0 dB Position

Jumper

Shown in

+3 dB Position

9

8. POWER Indicator LED.  Indicates when power is applied to the EXP9.  It stays on continuously even

when all zones are turned off (as long as AC power is applied to the plug-in power supply).

9. Video Gain Adjustment Jumpers (Internal. Refer to  Fig. 3).   As with the ZPR68-10, the video gain

of each zone on the EXP9 can be set to two levels, by the use of an internal jumper.  With the jumper
on one pin only of PJ1, the video gain is unity (0 dB).  When the jumper is inserted onto both pins of
PJ1, the video gain is increased by +3 dB.

You should use the +3 dB position only if you notice a reduction in picture contrast and brightness when
running long cable lengths (usually in excess of 150 feet).

Since the majority of applications will not require
additional gain, all EXP9's are shipped from the
factory with the jumper installed on one pin only
(0 dB).

To gain access to the jumpers you will need to
remove the top cover.  Remove the five screws on
each end and the screw just under the Video jacks
of the Zone Outputs.  

Do not  remove the screws

that secure the cover plates of unused zone slots.
Carefully lift the cover off.  When reassembling, be
sure to carefully align the holes in the top cover with
the jacks and the LEDs on all the PCB's before
pressing it down into place and replacing the screws.

CONNECTING THE EXP9 TO A ZPR68-10

To make the necessary con-
nections between the EXP9
Expander and a ZPR68-10, re-
fer to  Fig. 4 and proceed as
follows:

1. Be sure the power supply

for each unit is unplugged
when making connec-
tions.

2. If you are adding

"XCARDs" to an existing
EXP9, add them first.

3. Locate the 26 and the 50-

conductor ribbon cables
supplied with the EXP9.

4. Plug the connectors of

each cable into the mating
connectors on the ZPR68-
10 and the EXP9.

CAUTION:  The connec-
tors are keyed and will
mate in only one orienta-
tion.  DO NOT FORCE.
Be sure the red stripe is to
the right when plugging in,
as shown in Fig.4.

Fig. 3

  Video Gain Adjustment - Jumper Locations

Red Stripe

Red Stripe

50 Conductor
Ribbon Cable

(included)

26 Conductor
Ribbon Cable

(included)

ZPR68-10

EXP9 EXPANDER

VIDEO

AUDIO

L

R

ZONE IR INPUTS

ZONE  OUTPUTS

ZONE IR OUTPUTS

7

8

9

10

11

12

®

SYLMAR, CA • MADE IN U.S.A.

POWER

POWER
SUPPLY

EXP9

NINE ZONE EXPANDER

+12V

GND

STATUS

IR IN

13

14

15

ZONE OUTPUTS

COMMON IR OUTPUTS

COMMON IR INDICATOR

VIDEO

AUDIO

L

R

VIDEO

AUDIO

L

R

ZONE  CONTROL - IR INPUTS

1 2 3 4 5 6 7 8

COMMON IR LEVEL

H I
LO

SOURCE INPUTS

ZONE  OUTPUTS

1   2   3   4   5   6   7   8

ZONE IR OUTPUTS

1

2

3

4

5

6

7

8

1

2

3

4

5

6

®

SYLMAR, CA • MADE IN U.S.A.

POWER

IR CONFIRM

CO

G

POWER
SUPPLY

ZPR68-10

SIX ZONE EIGHT SOURCE REMOTE PREAMP

+12V

GND

STATUS

IR IN

COM

PORT

SOURCE INPUTS

ZONE  OUTPUTS

Fig. 4 

 Connecting the 26 & 50-Conductor Interface Ribbon Cables

Содержание EXP9

Страница 1: ...or in field expansion Whenreceivedfromthefactory unusedzoneopeningsarecoveredfromunderneathwithindividualcover plates These are removed as needed when additional zone XCARDs are installed in the field...

Страница 2: ...s receiving IR commands from an IR receiver keypad etc 4 I O PORT These multi pin connector jacks provide an input output port This allows the EXP9 to be linked with a ZPR68 10 via two large ribbon ca...

Страница 3: ...lly align the holes in the top cover with the jacks and the LEDs on all the PCB s before pressingitdownintoplaceandreplacingthescrews CONNECTING THE EXP9 TO A ZPR68 10 To make the necessary con nectio...

Страница 4: ...es in the top cover with the jacks and the LEDs on all the PCB s before pressing it down into place and replacing the screws INSTALLATION To install the ZPR68 10 EXP9 combination into the application...

Страница 5: ...dd up the current demands for the devices used in the system If the total current exceeds 1 8 A it is then necessary to use a 782 00 power supply to separately power the V or 12V terminals of the addi...

Страница 6: ...a system that is so extensive that the total current exceeds the 1 8 A limit of the EXP9 by more than 1000 mA use two 782 00 s connected so that two separate 12V DC rails are created Connect two group...

Страница 7: ...a different number The drawback to this solution is that you would need dedicated learning remotes if used for the rooms having the different IR Code Groups 4 I have two or more zone dedicated same br...

Страница 8: ...Max Total Current Available From 12V STATUS Terminals 1 8 A Power Requirements 14V 0 14V AC 2 7 A 8V 0 8V AC 0 7 A Multi Voltage Power supply included Gold Plated RCA type phono jacks All A V inputs...

Отзывы: