Modules & Connecting Blocks

796-20

4. The resistors in series with each zone and the common OUT port provides current sharing to each

emitter and also allows the use of dual emitters in combination with single emitters.  You may,
therefore, connect any combination of emitter models 282, 283, 284 & 286 series emitter series to the
zone ports and the common OUT port, to control the desired number of components.

5. When using fewer than 10 emitters on the 791-44 (common) emitter ports, you may plug them in

without regard to order, as shown in 

Fig. 2

.

6.

Considerations for Shielded Wire and Long Lead Lengths.

  When using long lengths (>50 ft.) of

inter-room shielded cable (> 75 ft. unshielded), it may be necessary to connect a 470 Ohm 1/8 Watt
resistor between IR 

IN

 (signal) and 

G

 at the 3-screw terminals of the 796-20.  Refer to 

Fig. 3

.

Please Note:

  The zone numbers for the

rooms in 

Fig. 2

 do 

not

 agree with the zone

numbers marked on the 796-20.  The reason
for this is that the 796-20 is designed to
expand the zones of a 795-20 as shown in

Fig. 4

, in which case the zone numbers do

match.

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

OUTPUT

+12V

IR IN

GND1

GND2

+12V

1 (ON)

0 (OFF)

1 2 3 4 5 6 7 8 910

ON

SENDER/

EMITTER

123456789

1

0

794

UNIVERSAL INTERF

ACE

A

B

A

B

A

B

ZONE 9

ZONE 8

ZONE 7

COMMON

ZONE IR INPUTS

ZONE 7

ZONE 8

ZONE 9

+12 IN G +12 IN G +12 IN G

ZONE 6

ZONE 5

ZONE 4

ZONE IR INPUTS

+12 IN G +12 IN G +12 IN G

A

B

A

B

A

B

ZONE 4

ZONE 5

ZONE 6

+12 OUT G

ZONE EMITTERS

ZONE EMITTERS

796-20

SIX ZONE CONNECTING BLOCK / EXPANDER

IR

CONFIRM

V V G S

POWER 15VAC

VIDEO

AUDIO
LEFT

INPUT

OUTPUT

AUDIO
RIGHT

1

2

3

4

SYLMAR, CA  •  MADE IN U.S.A.

®

RP41AV
REMOTE PREAMP

490-00 

Series

Micro Link™

IR Receivers

ZONE 4

3-Wire
Cable

GND

+12V

Red
Stripe

796-20

Six Zone

Connecting

Block

MAIN ROOM, EQUIPMENT CABINET, ETC.

283M

Blink IR™

GND

+12V

ZONE 5

780-10

J-Box

IR Receiver

3-Wire
Cable

GND

+12V

480-00

Dinky Link™

IR Receiver

Red
Stripe

GND

IR OUT

+12V

ZONE 2

CD Changer

Makita
Drape Controller

794-60

Universal

Interface

ZONE 6

490-00 

Series

Micro Link™

IR Receivers

ZONE 1

3-Wire
Cable

IR OUT

GND

+12V

Red
Stripe

To 120 V AC
(unswitched)

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™

COMMON

SOURCES

ZONE

EQUIPMENT

+12V

GND

3-Conductor Cable
(unshielded OK)

780-10

J-Box

IR Receiver

ZONE 3

OUT

V

IR

RCVR

PWR

G

S

291-10

Hidden Link™

IR Receiver

7-Foot Quick
Connect Cable

CB12

Connecting
Block

X

X

Do Not Use

These Jacks

AV 

Receiver 

Zone  1

AV 

Receiver 

Zone  2

AV 

Receiver 

Zone  3

Remote Preamp

AV 

Receiver 

Zone  4

AV 

Receiver 

Zone  6

283M

Blink IR™
Mouse Emitter

VCR 1

VCR 2

Laser Disc

Cable Box

Cassette DecK

791-44

Amplified

Connecting Block

283M

Blink IR™

283M

Blink IR™

283M

Blink IR™
Mouse Emitter

Smart
Pad™

 Zone  5

AM/FM 

Tuner 

Zone 5

RP41AV

GND

+12V

Satellite Receiver

+ 1 2   V D C

G N D

EMITTERS

12 VDC

HIGH

OUT

S TAT U S

I R   I N

IR

RCVR

791-

44

AMPLIFIED

CONNECTING BLOCK

®

ST
A

TUS

IR OUT

IR OUT

IR OUT

IR OUT

781RG

Power Supply

Fig. 2

  A Typical 796-20 Six Zone System

470

 Ohm

resistor

Shielded Cable(s)
to remote room(s)

796-20 Input
Terminals

Ground Shield as shown

ZONE 9

+12 I

N

 G

Fig. 3

  Using a 470 Ohm Capacitance Discharge Resistor