2
284-10
3-24-00
Amplifiers & Preamplifiers
• The diagram below illustrates a typical basic IR controlled system using the 284-10 emitters (as well as
a single 282-00 emitter).
• The 284-10 is designed to control two components. If only one is to be controlled, hide the extra emitter
behind the equipment. It may be used in the future if an extra component is added.
To 120 V AC
(unswitched)
781RG
Power Supply
789-44
Connecting Block
282-00
Emitter
EQUIPMENT CABINET, CLOSET, ETC.
Satellite Receiver
AV Receiver
VCR
Hand Held
Remote
291-10
IR Receiver
284-10
Dual Emitter Assembly
IR Sensor
Window
12VDC
+12 VDC
GND
STATUS
IR IN
EMITTERS
789-44
CONNECTING BLOCK
®
IR
RCVR
• DO NOT CUT the extra emitter wire in an attempt to remove it. The two emitters are wired in series. Cutting
or removing one emitter will prevent the other from working.
• CAUTION: If you cut off the plug for wired applications, be aware that the white striped side of the lead
is negative (--) for the 284-10 only. On all other Xantech emitters, the white stripe is positive.