background image

 

Freedom XF102- User Manual

 

 

WARNING: HAZARDOUS VAPORS. 

Spray materials, solvents, and other materials can be harmful

 

if inhaled or come in contact with the body. Vapors can cause severe nausea, fainting, or poisoning.

 

To avoid these risks, take the following preventions:

 

• Keep spray area well ventilated.

 

• Use a respirator or mask as vapors can be inhaled. Read all instructions supplied with the mask to ensure proper use.

 

• Wear protective eyewear.

 

• Wear protective clothing as required by disinfectant manufacturer.

 

 

WARNING: ELECTRIC SHOCK HAZARD

. May cause severe injury.

 

To avoid these risks, take the following preventions

 

• Keep charger electrical cord plug free from spray material and other liquids. Never hold cord at plug

 

connections to support cord or product. Failure to observe may result in an electrical shock and death.

 

• Never immerse electrical parts in water or any other liquid. 

 

• Do not expose atomizer, charger or battery pack to rain or wet conditions.

 

 

Unplug battery charger before cleaning.

 

• Do not abuse the cord. Never use the cord to carry the charger or pull the plug from an outlet. Keep cord away from heat, 

oil, sharp edges or moving parts. Replace charger if cord is damaged.

 

 

WARNING: SKIN INJECTION HAZARD

. May cause severe injury.

 

To avoid these risks, take the following preventions

 

• NEVER aim the atomizer at any part of the body.

 

• Do not aim the atomizer at or spray any person or animal.

 

• NEVER allow any part of the body to come in contact with the fluid stream.

 

• NEVER put your hand in front of the atomizer. 

 

- ALWAYS wear gloves while operating the unit; however, gloves will not provide protection against an injection injury.

 

• Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the    body.

 

• Always remove battery from the atomizer before servicing, cleaning tip guard or leaving unattended.

 

• Always use the nozzle tip guard. Do not operate atomizer without nozzle tip guard in place.

 

• Only use a nozzle tip specified by the manufacturer.

 

• Use caution when cleaning nozzle tips.

 

• High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection

 

occurs, seek medical attention immediately.

 

• Verify that all connections are secure before operating the unit.

 

 

 

Содержание XF102

Страница 1: ...Cordless Atomizer for Disinfecting INSTRUCTIONS FOR HVLP CORDLESS ATOMIZER XF102 Before using the atomizer read this manual thoroughly Any improper use can cause damage or serious injury including death ...

Страница 2: ...Freedom XF102 User Manual Disinfecting Log Sheet Area Disinfected Chemical Used Date Time ...

Страница 3: ...s that can explode or ignite Severe injury or property damage can occur Only clean up with water or soap water To avoid these risks take the following preventions Exhaust and fresh air introduction must be provided to keep the air within the spray area free from accumulation of flammable vapors Keep spray area well ventilated Avoid all ignition sources such as static electricity sparks open flames...

Страница 4: ...cord to carry the charger or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Replace charger if cord is damaged WARNING SKIN INJECTION HAZARD May cause severe injury To avoid these risks take the following preventions NEVER aim the atomizer at any part of the body Do not aim the atomizer at or spray any person or animal NEVER allow any part of the body to come...

Страница 5: ... damage take the following actions Always wear appropriate gloves eye protection and a respirator or mask when disinfecting Do not aim the atomizer at or spray any person including self or animal Do not spray outdoors on windy days Wear protective clothing to keep spray material off skin and hair Follow all appropriate local state and national codes governing ventilation fire prevention and operat...

Страница 6: ...Freedom XF102 User Manual ...

Страница 7: ...ard 29 Trigger 46 Motor gasket 13 Nozzle seal 30 Spray a knob 47 Fan 14 Needle 31 Left side cover 48 Fan cover 15 Needle insert 32 O ring 49 Damping ring 16 Needle seat 33 Atomization circle 50 Battery Charger XC101 17 bowl seals 34 Vent spring II Technical parameters Model XF102 Rated power 120W Atomized particle size nominal 90 120 microns when used with water thin disinfectant Rated voltage 20V...

Страница 8: ...b If spraying downward the angled end of the suction tube should be pointing toward the front of the atomizer c Do not operate nor store atomizer on its side or inverted when liquid is in the canister d The suction tube in the canister should always be submerged in the liquid in the canister when in use Do not operate the atomizer in a manner attitude that allows the suction tube to become unsubme...

Страница 9: ... it counterclockwise 90 degrees c Pull out to remove the motor blower from the atomizer 6 Screw filled disinfectant container onto the atomizer 7 Connect atomizer body with motor blower a Hold atomizer body in your left hand and align the slot on the atomizer with the slot on the motor blower and insert as shown in the figure b Rotate the motor blower 90 degrees clockwise c When the atomizer and m...

Страница 10: ...ting screw to meet your desired level of disinfectant coverage a Adjust the screw to the left to decrease coverage b Adjust the screw to the right to increase coverage 9 Spray pattern adjustment Turn the knob to adjust from round pattern to fan pattern ...

Страница 11: ...should be 4 feet or greater from the surface being disinfected Surfaces being sprayed should be completely dry within 5 10 minutes of spraying Wiping wet disinfectant off the surfaces should not be required However the surfaces should remain wet long enough dwell time for the disinfectant to be effective at least one minute See disinfectant manufacturer s recommendations for dwell time for the spe...

Страница 12: ...mately 200 mL of water to disinfectant container A few drops of liquid soap or dishwashing liquid can also be added f Reassemble container to atomizer then assemble atomizer with motor blower g Swish water in container to wet the interior of the container and to mix in soap if used h Reattach battery pack i Turn on atomizer and run until container is empty j Repeat steps above one additional time ...

Страница 13: ...ED UP BY ENSURING THE PACK AND CHARGER ARE IN A NORMAL INDOOR ROOM TEMPERATURE ENVIRONMENT IDEALLY 60 F TO 80 F 3 Battery pack fuel gauge a The battery pack has a fuel gauge to help the user understand approximately how much capacity is left in the battery charge Push the button on pack to light the indicators i 3 LEDs indicates the pack is above 40 charged ii 2 LEDs indicates the pack is between ...

Страница 14: ...tern runs sags or remains wet 1 applying too much material 1 adjust material flow or increase movement of atomizer F too much over spray 1 atomizer too far from target area 2 too much material applied 1 reduce distance 2 turn material volume setting to right G pattern is very light and splotchy 1 moving the atomizer too fast 1 adjust material flow or decrease movement of atomizer H large cloud of ...

Страница 15: ...Freedom XF102 User Manual Xanigo llc 3236 Huntington Weston FL 33332 https xanigo com Contact Us 800 514 7837 info xanigo com support xanigo com 07 2021 ...

Отзывы: